Cleaning/Checking Or Replacing The Fan - gefran GFW-Xtra 40 Installation And Operation Manual

Modular power controller with overcurrent fault protection
Table of Contents

Advertisement

2.8
c
/
leaninG
PERIODIC CLEANING
Every 6-12 months (depending on the dust level of the installation) blow a compressed air jet downward through the
upper rectangular cooling grilles (on the side opposite the fan).
This will clean the internal heat dissipater and the cooling fan.
IN CASE OF OVERHEAT ALARM
If periodic cleaning does not eliminate the problem, do as follows:
a Remove the fan support grille by detaching the two support tabs
b Disconnect the fan connector from the board
c Check the condition of the fan
d Clean or replace the fan
Attention: check that the arrow (on the fan) indicating the direction of air flow is pointing to the heat sink
e Insert the connector into the board
f Insert the fan support grille until it attaches
g Power up the device and check fan rotation when at least one load is on
Figure 5
1�
Fan
2�
Lower grille (ventilation intake)
3�
Detail of insertion of fan connector in PCB
10
checkinG or rePlacinG the fan
Fan Air
Direction
80993B_MHW_GFW-Xtra_06-2018_ENG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfw-xtra 60Gfw-xtra 100

Table of Contents