System Coniguration Settings - Graco Reactor 2 Hydraulic Operation

Proportioning systems
Table of Contents

Advertisement

Error Codes and Troubleshooting
Job Log
Log
Job
Job
Log
The job log ile name is 2 JOB.CSV and is stored
in the DATAxxxx folder.
The job log maintains a record of data points based on
the USB Log Frequency deined in the Setup screens.
The ADM stores the last 237,000 data points for
download. See
Advanced Setup Screens, page
for information on setting the Download Depth and
USB Log Frequency.
• Data point date
• Data point time
• A side temperature
• B side temperature
• Hose temperature
• A side temperature setpoint
• B side temperature setpoint
• Hose temperature setpoint
• Pressure A
• Pressure B
• A side inlet pressure (Elite only)
• B side inlet pressure (Elite only)
• A side inlet temperature (Elite only)
• B side inlet temperature (Elite only)
• Inlet pressure setpoint
• System lifetime pump cycle counts
• Usage Volume (manual)
• Pressure, volume, and temperature units
• Job name/number
Daily
Daily Log
Daily
Log
Log
The daily log ile name is 3 DAILY.CSV and is stored
in the DATAxxxx folder.
The daily log maintains a record of the total cycle
and volume sprayed on any day that the system is
powered up. The volume units will be the same units
that were used in the Job Log.
62
The following data is stored in this ile:
• Date that material was sprayed
• Time
unused column
• Total pump cycle count for day
• Total volume sprayed for day
System Software
Software Log
System
System
Software
35,
The system software ile name is 4 SYSTEM.CSV
and is stored in the DATAxxxx folder.
The system software log lists the following:
• Date log was created
• Time log was created
• Component name
• Software version loaded on the above component
Blackbox Log
Log File
Blackbox
Blackbox
Log
The black box ile name is 5 BLACKB.CSV and is
stored in the DATAxxxx folder.
The Blackbox log maintains a record of how the
system runs and the features that are used. This log
will help Graco troubleshoot system errors.
Diagnostics Log
Diagnostics
Diagnostics
The diagnostics ile name is 6 DIAGNO.CSV and is
stored in the DATAxxxx folder.
The Diagnostics log maintains a record of how the
system runs and the features that are used. This log
will help Graco troubleshoot system errors.
System Coniguration
Coniguration Settings
System
System
Coniguration
The system coniguration settings ile name is
SETTINGS.TXT and is stored in the DOWNLOAD
folder.
A system coniguration settings ile automatically
downloads each time a USB lash drive is inserted
into the ADM. Use this ile to back up system
settings for future recovery or to easily replicate
settings across multiple systems. Refer to the
Upload Procedure, page 63
to use this ile.
Log
Log
File
File
Log File
File
Log
File
Settings
Settings
for instructions on how
334945C