Connect Power - Graco Reactor 2 Hydraulic Operation

Proportioning systems
Table of Contents

Advertisement

Setup
Connect

Connect Power

Connect
Power
Power
NOTE: All electrical wiring must be done by a
NOTE:
NOTE:
qualiied electrician and comply with all local codes
and regulations.
1. Turn main power switch (MP) OFF.
2. Open electrical enclosure door.
NOTE: Terminal jumpers are located inside the
NOTE:
NOTE:
electrical enclosure door if equipped.
3. Install supplied terminal jumpers in the positions
shown in image for the power source used (H-30
and H-XP2 models only).
4. Route power cable through strain relief (EC) in
electrical enclosure.
5. Connect incoming power wires as shown in
image. Gently pull on all connections to verify
they are properly secured.
6. Verify all items are connected properly as shown
in image then close electrical enclosure door.
30
Table 5 5 5 Power
Power Cord
Table
Table
Power
Model
Model
Model
Input
Input
Input Power
H-30, 10.2
200-240 VAC,
kW
1 Phase
200-240 VAC,
3 Phase, DELTA
350-415 VAC,
3 Phase, WYE
H-30, 15.3
200-240 VAC,
kW
1 Phase
200-240 VAC,
3 Phase, DELTA
350-415 VAC,
3 Phase, WYE
H-XP2,
200-240 VAC,
15.3 kW
1 Phase
200-240 VAC,
3 Phase, DELTA
350-415 VAC,
3 Phase, WYE
H-40, 15.3
200-240 VAC,
kW
3 Phase, DELTA
350-415 VAC,
3 Phase, WYE
H-40, 20.4
200-240 VAC,
kW
3 Phase, DELTA
ti26342a_17D775
350-415 VAC,
3 Phase, WYE
H-50, 20.4
200-240 VAC,
kW
3 Phase, DELTA
350-415 VAC,
3 Phase, WYE
H-XP3,
200-240 VAC,
20.4 kW
3 Phase, DELTA
350-415 VAC,
3 Phase, WYE
*Values are for reference only. Refer to amperage
listed in Models table (see
system and compare against latest version of local
electrical code to select proper power cord size.
NOTE:
NOTE: 350 415 VAC systems are not designed to
NOTE:
operate from 480 VAC power source.
Cord Requirements
Requirements
Cord
Requirements
Power
Power
Cord Speciications*
Cord
Cord
Speciications*
Speciications*
AWG (mm^2)
AWG
AWG
(mm^2)
(mm^2)
4 (21.2),
2 wire + ground
8 (8.4),
3 wire + ground
8 (8.4),
4 wire + ground
4 (21.2),
2 wire + ground
6 (13.3),
3 wire + ground
8 (8.4),
4 wire + ground
4 (21.2),
2 wire + ground
6 (13.3),
3 wire + ground
8 (8.4),
4 wire + ground
6 (13.3),
3 wire + ground
8 (8.4),
4 wire + ground
4 (21.2),
3 wire + ground
6 (13.3),
4 wire + ground
4 (21.2),
3 wire + ground
6 (13.3),
4 wire + ground
4 (21.2),
3 wire + ground
6 (13.3),
4 wire + ground
Models, page 9