Manual Hose Heat Mode - Graco Reactor 2 Hydraulic Operation

Proportioning systems
Table of Contents

Advertisement

Manual
Manual Hose
Manual
Hose
Hose Heat
Heat Mode
Heat
If the system produces the T6DH Sensor Error Hose
alarm or the T6DT Sensor Error TCM alarm, use
manual hose heat mode until the hose RTD cable or
FTS temperature sensor can be repaired.
Do not use Manual Hose Mode for extended periods
of time. The system performs best when the hose has
a valid RTD signal and can operate in temperature
control mode. If a hose RTD breaks, the irst priority
is to ix the RTD. Manual Hose Mode can help inish
a job while waiting for repair parts.
Enable
Enable Manual
Enable
Manual Hose
Manual
Hose Mode
Hose
1. Disconnect the hose RTD sensor from the TCM.
2. Enter Setup Mode and navigate to System
Screen 2.
334945C
Mode
Mode
Mode
Mode
3. Select Enable Manual Hose Mode.
NOTE:
NOTE: When manual hose mode is enabled, the
NOTE:
manual hose mode advisory EVCH-V will appear.
4. Enter Run Mode and navigate to the Target
screen. Use the up and down arrows to set the
desired hose current.
Hose Current
Hose
Hose
Current Settings
Current
Settings Hose
Settings
Default
Maximum
Spraying
Hose Current
Hose
Current
Current
20A
37A
51