Maintenance; Preventative Maintenance Schedule; Proportioner Maintenance - Graco Reactor 2 Hydraulic Operation

Proportioning systems
Table of Contents

Advertisement

Maintenance

Maintenance
Maintenance
Prior to performing any maintenance procedures,
follow
Pressure Relief Procedure, page
Preventative
Preventative Maintenance
Preventative
Maintenance Schedule
Maintenance
The operating conditions of your particular system
determine how often maintenance is required.
Establish a preventive maintenance schedule by
recording when and what kind of maintenance is
needed, and then determine a regular schedule for
checking your system.
• Inspect hydraulic and luid lines for leaks daily.
• Clean up all hydraulic leaks; identify and repair the
cause of the leak.
• Inspect luid inlet strainer screens daily. See below.
• Keep component A from exposure to moisture to
prevent crystallization.
• Check hydraulic luid level weekly. Check
hydraulic luid level on a dipstick. Fluid level
must be between indent marks on dipstick.
Reill as required with approved hydraulic luid,
Technical Speciications
Speciications and the Approved
see Technical
Technical
Speciications
Anti-Wear (AW) Hydraulic Oils table in the Reactor
Repair-Parts manual 334946. If luid is dark in
color, change luid and ilter.
• Change break-in oil in a new unit after the irst 250
hours of operation or within 3 months, whichever
comes irst. See the table below for recommended
frequency of oil changes.
334945C
Table
Table
Table 6 6 6 Frequency
Ambient
Ambient
Temperature
Temperature
0° to 90° F
(-17° to 32° C)
54.
90° F and above
Schedule
Schedule
(32° C and above)

Proportioner Maintenance

Proportioner
Proportioner
Fluid Inlet
Fluid
Fluid
Inspect luid inlet strainer screens daily, see
Fluid Inlet Strainer Screens, page
Grease Circulation
Grease
Grease
Grease circulation valves (SA and SB) with Fusion
grease (117773) weekly.
ISO
ISO Lubricant
ISO
Inspect ISO lubricant level and condition
daily. Reill or replace as needed. See
Pump Lubrication System, page
Moisture
Moisture
Moisture
To prevent crystallization, do not expose component
A to moisture in air.
Gun
Gun Mix
Gun
Clean gun mix chamber ports regularly. See gun
manual.
Frequency of of of Oil
Frequency
Oil
Oil Changes
Ambient
Recommended
Recommended
Recommended
Temperature
Frequency
Frequency
Frequency
1000 hours or 12 months,
whichever comes irst
500 hours or 6 months,
whichever comes irst
Maintenance
Maintenance
Inlet Strainer
Strainer Screens
Screens
Inlet
Strainer
Screens
Circulation Valves
Valves
Circulation
Valves
Lubricant
Lubricant Level
Level
Level
Mix Chamber
Mix
Chamber Ports
Chamber
Ports
Ports
Maintenance
Changes
Changes
57.
59.
57

Advertisement

Table of Contents
loading

Table of Contents