System 1; System 2; System 3; Recipes - Graco Reactor 2 Hydraulic Operation

Proportioning systems
Table of Contents

Advertisement

Advanced Display Module (ADM) Operation
System

System 1 1 1

System
Use this screen to set the activation pressure for the
Pressure Imbalance Alarm and Deviation, enable or
disable diagnostic screens, set the maximum and
minimum drum volume, and enable drum alarms.

System 2 2 2

System
System
Use this screen to enable Manual Hose Mode
and inlet sensors, as well as setting the inlet
sensor low pressure alarm and low temperature
deviation. Manual Hose Mode disables the hose
temperature RTD sensor so the system can
operate if the sensors were to malfunction (see
Manual Hose Heat Mode, page 51
information). Default settings are 10 psi (0.07 MPa,
0.7 bar) for low inlet pressure alarm and 50˚F (10˚C)
for low inlet temperature deviation.
36

System 3 3 3

System
System
Use this screen to enable alternate pump cylinder
sizes, to turn motor standby mode on and off, and
to enable recirculation cycle count. Cycles below
700 psi outlet pressure will not be counted unless
enabled.

Recipes

Recipes
Recipes
Use this screen to add recipes, view saved recipes,
and enable or disable saved recipes. Enabled
recipes can be selected at the Home Run Screen. 24
recipes can be displayed on the three recipe screens.
for more
334945C

Advertisement

Table of Contents
loading

Table of Contents