NOTE:
It is recommended to install an outside air inlet of minimum 4" diameter in the room where the heating appliance is
installed (see drawing below). To do so, it is preferable to choose a wall which is not exposed to extreme winds,
according to the conditions surrounding your house.
Free air
entry
N
.B. The owner of the furnace is responsible for the room salubrity in case of negative pressure or temporary
negative pressure.
E
LECTRICAL CONNECTION
The following instructions do not supersede the local cod
W
OOD ONLY
Installed limit control on support
the furnace), and connected to the electrical box along with the transformer. Install the servo-motor on the front facade
above the door, on the right side (use pre-drilled holes). The chain that links the air inlet latch to the motor must have a
play of 1/8 in. When there is no call for heat, the air inlet latch must be completely shut and the chain must be affixed
to the servo-motor at "8 o'clock".
The switch located on the fan limit control activates high speed operation, in either automatic or manual (continuous
operation) modes.
Th
e switch located on the electric unit controls low speed operation, in either ON (continuous operation) or OFF
modes.
W
ARNING: USE FEEDING WIRES SUITABLE FOR 75
W
OOD/ELECTRIC
The limit control is a manual reset thermostatic captor and is located directly inside the electric element (see
WIRING DIAGRAMS). The electric elements must be installed as shown on the diagram. Install the combined limit
control on the support provided, at the determined location. The connections must conform to the diagram.
Install the servo-motor on the front façade above the door, on the right side (use pre-drilled holes). The chain that
links the air inlet latch to the motor must have a play of 1/8 in. When there is no call for heat, the air inlet latch must be
completely shut and the chain must be affixed to the servo-motor at "8 o'clock".
Exterior
wall
provided on p
roper location of the appliance (two holes are predrilled on the edge of
*
Insulated conduit full lenght