Wood/Electric Furnaces Psg 5000 40Kw @ 60Kw - PSG G1N 4R9 Installation And Operating Instructions Manual

Wood and combined wood-electric furnaces
Table of Contents

Advertisement

HONEYWELL
WHITE RODGERS
L4064
ON 150°F
F
L
BLACK FROM
L
F
RED
TRANSFO
OFF 110°F
LIMIT 250°F
BLACK
ELEMENTS
E
POWER
BLOCK
110 VOLT LINE
3/4 H.P. MOTOR
B
C
A
240 V
240V
L1
N
L2
L- 160
20 A
6
IMPORTANT:
IT IS MANDATORY TO CHANGE THE
TRANSFORMER 120-24 FOR A 240-24
IF YOU USED 3/4 H.P. MOTOR ON 240 V
A
B C
POWER
TRANSFO
BLOCK
BLACK
120V
COMMAND
POWER
E
1
BLOCK
BLOCK
24V
BLACK
COMMAND
1
6
RELAY
BLOCK
20VA
BLOWER
WHITE
BLACK
1
2
3
4
5
20 KW @ 30KW
COMMAND
BLOCK

WOOD/ELECTRIC FURNACES PSG 5000 40KW @ 60KW

BELT-DRIVE G12 MOTOR
CONTACTOR
COIL
24V
40 A IND/50A RES
PER PÔLE
600 V.A.C. MAX.
BLOC
4
TRANSFO
COMMANDE
240V
24V
SEQUENCER
RELAY
40VA
POWER
7
B
BLOCK
POWER
A
BLOCK
5 KW ELEM.
F- 110
5 KW ELEM.
5 KW ELEM.
5 KW ELEM.
7
8
D
E
F
5 KW ELEM.
2
1
8
7
RELAY
2
1
8
3
4
5
6
RELAY
6
7
8
3
4
5
3
ELECTRIC
9
10
THERMOSTAT
4
WHITE RODGERS
L
F
SERVO
BLACK
MOTOR
1
WOOD
THERMOSTAT
2
B
C
IMPORTANT:
IT IS MANDATORY TO CHANGE THE
TRANSFORMER 120-24 FOR A 240-24
IF YOU USED 3/4 H.P. MOTOR ON 240 V
TRANSFO
BLACK
120V
POWER
E
BLOCK
24V
BLACK
1
RELAY
20VA
7
6
20 KW @ 30KW
24
HONEYWELL
L4064
ON 150°F
F
L
BLACK FROM
RED
TRANSFO
OFF 110°F
LIMIT 250°F
ELEMENTS
TRANSFO
240V
E
POWER
24V
BLOCK
RELAY
40VA
110 VOLT LINE
3/4 H.P. MOTOR
A
240 V
POWER
240V
BLOCK
L1
N
L2
5 KW ELEM.
L -160
F -110
5 KW ELEM.
20 A
5 KW ELEM.
6
5 KW ELEM.
A
B
C
D
E
F
POWER
5 KW ELEM.
BLOCK
COMMAND
1
BLOCK
COMMAND
6
BLOCK
BLOWER
WHITE
BLACK
1
2
3
4
5
6
7
8
COMMAND
BLOCK
CONTACTOR
COIL
24V
40 A IND/50A RES
PER POLE
600 V.A.C. MAX.
COMMAND
4
BLOCK
SEQUENCER
POWER
7
B
BLOCK
A
7
8
2
1
8
7
RELAY
3
4
5
6
3
ELECTRIC
THERMOSTAT
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psg-2000Psg-3000Psg-4000Psg-4500Psg-5000

Table of Contents