FAN LIMIT HONEYWELL L6064(MOTOR (G-10) 4 SPEED AND (G-12) 2 SPEED)
ELEMENTS
HONEYWELL
POWER
BLOCK
L6064
E
240V
FAN
LIMIT
ON 150°F
L1
N
OFF 110°F
LIMIT 250°F
LINE
LOAD
LOW
HIGH
LINE
B
A
C
TRANSFO
POWER
BLACK
120V
COMMAND
E
1
BLOCK
24V
BLACK
COMMAND
1
6
RELAY
20VA
BLOWER
4 SPEED
MOTOR
TERMINAL
15 KW @ 30KW
S3
S4
S2
S5
S1
S6
CONNECTORS INDENTIFICATION OF THE SEQUENCER

WOOD/ELECTRIC FURNACES

25 KW OR 30 KW ONLY
L2
TRANSFO
BLACK
BLACK/RED
20 A
L -170 RESET
6
BLOCK
POWER
BLOCK
A
B
C
D
BLOCK
HIGH
MED HIGH
MOVE THIS WIRE
TO CHANGE MOTOR SPEED
MED LOW
LOW
COMMON
1
2
3
4
5
REVISION JUNE 16TH 2005
CONTACTOR
COIL
24V
40 A IND/50A RES
PER POLE
600 V.A.C. MAX.
COMMAND
4
BLOCK
240V
24V
SEQUENCER
RELAY
40VA
7
S1
S3
POWER
A
BLOCK
S1
S2
5 KW ELEM.
FAN
S1
S3
1
5 KW ELEM.
S2
5 KW ELEM.
2
S1
3
S1
S3
5 KW ELEM.
S1
E
F
S1
S3
5 KW ELEM.
S1
2
1
8
RELAY
3
4
5
COMMAND
6
7
8
BLOCK
18
POWER
B
BLOCK
S4
S6
S6
S5
S5
S6
S4
S6
S6
S4
S6
7
8
S6
S4
S5
S6
7
1
WOOD
THERMOSTAT
2
6
3
ELECTRIC
THERMOSTAT
4
5
SERVO
MOTOR
6