REF 16241 / 16242
Physical Dimensions
Phoroptor Head
Spherical Effects ................................................................................................... +17.75 to -22.25 D
Steps ........................................................................................................................... 0.25 and 1.0 D
Cylinder Power .............................................................................................................. -8.0 to +8.0 D
Steps ........................................................................................................................... 0.25 and 1.0 D
Axis Adjustment ................................................................................................................... 0° to 180°
Steps .................................................................................................................................. 1° and 10°
Cross Cylinder Test ................................................................................................................ ±0.25 D
Prismatic Effects (Optional) ........................................................................................+ 0.20Δ per eye
Steps ............................................................................................................................0.50Δ per eye
Corneal Vertex Distance ........................................................................................................... 16 mm
Pupil Distance ................................................................................................................. 50 to 80 mm
Steps .......................................................................................................................... 1 mm binocular
Convergence .......................................................................................................................... 400 mm
Height Level of Eyes, adjustment ............................................................................................. ±3 mm
Leveling ...................................................................................................................... via bubble level
Free Aperture ........................................................................................................................... 19 mm
Thickness of Housing at the Viewing Aperture ......................................................................... 26 mm
W x H x D (at PD = 64 mm) ..................................................31 x 20.3 x 7.1 cm (12.2 x 8 x 2.8 in.)
Weight With Mount and Without Prism Compensator ............................................... 4.42 kg (9.75 lb)
Weight With Mount and With Prism Compensator .................................................. 4.65 kg (10.25 lb)
Weight Without Mount and Without Prism Compensator .......................................... 3.95 kg (8.70 lb)
Weight Without Mount and With Prism Compensator ............................................... 4.17 kg (9.20 lb)
Controller With Display
Controller (W x H x D) ......................................................23.4 x 4.6 x 16.8 cm (9.9 x 1.5 x 6.9 in.)
Display (W x H x D) ........................................................22.4 x 15.7 x 1.5 cm (10.0 x 7.0 x 2.8 in.)
Display Size (Diagonal) .......................................................................................... 10.0 in. (25.4 cm)
Total Height with Display ........................................................................................... 8.4 in. (21.3 cm)
Weight ....................................................................................................................... 6.40 lb (2.90 kg)
Central Unit
Physical Dimensions
Width
Height
Depth
Weight
Electrical
Model
Input Voltage
Frequency
Current (max.)
Fuses
Ports: (1 each)
Phoroptor, Controller (Keypad), Projector, Printer, Instrument 1 I/O, Instrument 2 I/O,
EMR Port, Transfer Port
104
20.1 cm (7.9 in.)
8.9 cm (3.5 in.)
26.7 cm (10.5 in.)
3.2 kg (7.1 lb)
16219
100 - 240V~
50 - 60 Hz
60 VA
T2AL 250V
0.25Δ per eye
16241-101 Rev. D