Operating The Projector; Performing Initial System Start-Up - Christie Mirage SST User Manual

Hide thumbs Also See for Mirage SST:
Table of Contents

Advertisement

Operating the projector

Learn how to turn on and off the projector and the meaning of the status indicators.

Performing initial system start-up

Learn how to turn on all components of the Mirage SST system for the first time: chiller, laser
illumination source, and projector head.
Warning! If not avoided, the following could result in death or serious injury.
SHOCK HAZARD! Do not attempt operation if the AC supply is not within the specified voltage
and current, as specified on the license label.
Never run the laser illumination source without the cooling system already running. The chiller must
be the first item turned on before power is applied to the laser rack and kept operating until after the
AC lockout/switch is rotated to the off position.
1. Verify the coolant lines are connected correctly.
2. Fill the chiller reservoir with the required coolant (30% Propylene Glycol coolant).
3. Turn on the chiller, set the temperature to between 19°C (66°F) to 22°C (71.6°F).
For more information on how to turn on the chiller, refer to the chiller's product
documentation.
4. Check the coolant level in the reservoir and hoses and top up the coolant as required.
5. Check that no leaks exist in the system.
6. Allow the chiller to run until the system is operating with no new bubbles entering the
reservoir. Add additional coolant as necessary.
7. On the laser illumination source, rotate the main AC lockout/switch (A)to the on position and
rotate the Power key (B) clockwise to the on position.
The Interlock status indicator (C) on the laser illumination source turns yellow.
Mirage SST User Guide