Planet IGS-5225 Series User Manual page 401

L2+ ring managed gigabit ethernet switch
Hide thumbs Also See for IGS-5225 Series:
Table of Contents

Advertisement

• Interval Time (10~300s)
• Retry Count (1~5)
• Action
• Reboot Time (30~180s)
Buttons
: Click it to save changes.
: Click it to reset configuration which doesn't to be saved yet.
to the PoE device. Please be noticed that the PD's IP address must be set to the
same network segment with IGS-5225-4UP1T2S/8P4S/8P2S/8P2S2X PoE Switch.
This column allows user to set how long system should be issue a ping request to
PD for detecting PD is alive or dead. Interval time range is from 10 seconds to 300
seconds.
This column allows user to set how many times system rerry ping to PD. For
example, if we set count 2, the meaning is that if system retry ping to the PD and the
PD doesn't response continuously, the PoE port will be reset.
Allows user to set which action will be apply if the PD witout any response.
IGS-5225-4UP1T2S/8P4S/8P2S/8P2S2X PoE Switch offers 3 actions as following.
 PD Reboot: It menas system will reset the PoE port that connected the PD.
 Reboot & Alarm: It means system will reset the PoE port and issue an alarm
message via Syslog, SMTP.
 Alarm: It means system will issue an alarm message via Syslog, SMTP.
This column allows user to set the PoE PD device rebooting time, due to there are
so many kind of PoE PD device on the market and theyhave different rebooting
time. The PD Alive-check is not a defining standard, so the PoE PD device on the
market doesn't report reboots done information to IGS-6325 PoE Switch, so user
has to make sure how long the PD will be finished to boot, and then set the time
value to this column.
System is going to check the PD again according to the reboot time. If ou can not
make sure precisely booting time, we suggest you to set it longer.