Planet IGS-5225 Series User Manual page 362

L2+ ring managed gigabit ethernet switch
Hide thumbs Also See for IGS-5225 Series:
Table of Contents

Advertisement

The page includes the following fields:
Object
Ingress Port
• Policy Filter
• Policy Value
• Policy Bitmask
Frame Type
Action
Rate Limiter
• Port Redirect
• Mirror
Description
Select the ingress port for which this ACE applies.
Any: The ACE applies to any port.
Port n: The ACE applies to this port number, where n is the number of the
switch port.
Specify the policy number filter for this ACE.
Any: No policy filter is specified. (policy filter status is "don't-care".)
Specific: If you want to filter a specific policy with this ACE, choose this
value. Two field for entering an policy value and bitmask appears.
When "Specific" is selected for the policy filter, you can enter a specific policy value.
The allowed range is 0 to 255.
When "Specific" is selected for the policy filter, you can enter a specific policy bitmask.
The allowed range is 0x0 to 0xff.
Select the frame type for this ACE. These frame types are mutually exclusive.
Any: Any frame can match this ACE.
Ethernet Type: Only Ethernet Type frames can match this ACE. The IEEE
802.3 describes the value of Length/Type Field specifications to be greater
than or equal to 1536 decimal (equal to 0600 hexadecimal).
ARP: Only ARP frames can match this ACE. Notice the ARP frames won't
match the ACE with Ethernet type.
IPv4: Only IPv4 frames can match this ACE. Notice the IPv4 frames won't
match the ACE with Ethernet type.
IPv6: Only IPv6 frames can match this ACE. Notice the IPv6 frames won't
match the ACE with Ethernet type.
Specify the action to take with a frame that hits this ACE.
Permit: The frame that hits this ACE is granted permission for the ACE
operation.
Deny: The frame that hits this ACE is dropped.
Specify the rate limiter in number of base units.
The allowed range is 1 to 16.
Disabled indicates that the rate limiter operation is disabled.
Frames that hit the ACE are redirected to the port number specified here.
The allowed range is the same as the switch port number range.
Disabled indicates that the port redirect operation is disabled.
Specify the mirror operation of this port. Frames matching the ACE are mirrored to the
destination mirror port. The rate limiter will not affect frames on the mirror port. The
allowed values are:
User's Manual of IGS-5225 series
362

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents