General DataComm SpectraComm V.34 Installation & Operation Manual page 26

Dual modem
Table of Contents

Advertisement

System Description
Table 1-3
Technical Specifications
Specification
Pulse Dial Ratio USA
Ring Cadence
DC Loop
Current
Call Progress
Monitor
Power Reqmts
DC Voltage
(Typical)
Dimensions
Environment
Note
Receiver performance in ITU-T V.34, V.32 bis, and V.32 modes may be degraded when transmitting above
-6 dBm.
Note
ITU-T V.34/V.32/V.32 bis, being echo canceling protocols, use signal quality as criteria for maintaining
connection. They also provide for self-training detection to force disconnect.
1-12
Description
International
USA
International
USA
International
BUSY
CONNECT (rate)
(Refer to ITU-T V.42 options for
delay)
CONNECT (
Refer to ITU-T V.42 options for
delay)
NO ANSWER
NO CARRIER
NO DIAL TONE
OK (character abort)
RING
RINGING
UNOBTAINABLE NUMBER
Power Consumption
+5V
+12V
-12V
Printed circuit board
Temperature
Operating Humidity
Operating Altitude
SpectraComm Dual V.34 Modem
Installation and Operation
Technical Specifications
Detail
Make/Break: 39/61%
Per Country requirements
On 2 seconds; Off 4 seconds
Per Country requirements
20-80 milliamps
Per Country requirements
(Refer to ITU-T V.42 options for CONNECT delay)
6 watts dc maximum each
+5V ±5% at 0.85A
+12V ±5% at 0.04A
-12V ±5% at 0.015A
Load Number - 1.0
Height: 21 mm (0.81 in)
Width: 178 mm (7.0 in)
Depth: 241 mm (9.5 in)
Operating: 0 to 50°C (32° to 122°F)
Non-operating: -40 to 70°C (-40° to 158°F)
Up to 95% humidity (non-condensing)
0 m to 3,047 m (0 to 10,000 ft)
060R122-000
Issue 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

060p027-002060m027-002060a027-001060a027-006

Table of Contents