V.25 bis Command Set Operation
3. Hang up the handset. You may now commence data communications.
4. To terminate communication, turn Off terminal interface circuit 108.1.

V.25 bis 108.2 Mode Interface Specifications

Physical connections between a DTE and a DCE may be either synchronous or asynchronous. The
ITU-T V.25 bis 108.2 mode recommendations describe the exchange of commands and responses
between the units using both types of operation. The V. 34 supports command/response exchange
in either mode.
The following paragraphs describe the functional characteristics of the V.25 bis synchronous and
asynchronous interfaces, as used in the Dual V.34 Modem.

Interface Connections

From DCE to DTE:
104
RXD
106
CTS
107
DSR
125
Call Indicator/Ring Detector
114
TX Timing (synchronous only)
115
RX Timing (synchronous only)
From DTE to DCE:
103
TXD
105
RTS
108.2 DTR
113
TX Timing (synchronous only)
5-12