C
3
HAPTER
TABLE 1. 3-Boom Valve Wire Connections
Boom Switch Number
1+
1 -
2+
2 -
3+
3 -
TABLE 2. 5-Boom Valve Wire Connections
Boom Switch Number
1+
1 -
2+
2 -
3+
3 -
4+
4 -
5+
5 -
5. Locate the appropriate AccuBoom wire connector from the 10-wire bundle for the 1+ boom switch.
NOTE:
The AccuBoom Connector column represents the wire colors that correspond to the appropriate
boom switch. For example, the AccuBoom wire for the 1+ boom switch is black.
6. Locate the parallel positive boom switch wire that was disconnected in step 4.
NOTE:
The SpraCoupe Wire Number column indicates the wire number printed on the parallel positive and
negative wires that correspond to the appropriate boom switch. For example, if the machine has three
boom sections, the SpraCoupe parallel positive wire for the 1+ boom switch is labeled 505B.
12
AccuBoom Connector
Black
Gray
Brown
Yellow
Blue
Orange
Black/White
Purple
Brown/White
Green
AccuBoom Connector
Black
Gray
Brown
Yellow
Blue
Orange
Black/White
Purple
Brown/White
Green
SpraCoupe 3000/4000 with SCS 460 Console AccuBoom Installation Manual
Connector Sheilding
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Connector Sheilding
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
SpraCoupe Wire
Number
505B
506B
507B
508B
509B
510B
Not Connected
Not Connected
Not Connected
Not Connected
SpraCoupe Wire
Number
503B
504B
505B
506B
507B
508B
509B
510B
511B
512B