FIGURE 6. Boom Switch Console
1. Remove the four screws (shown in the figure above) used to secure the cover on the boom switch console.
2. Carefully remove the cover of the boom switch console.
3. Locate the parallel positive and negative wires located at the bottom of boom switch 1.
NOTE:
The positive boom switch wire has an adapter that allows two wires to be connected to the switch
connector (parallel). The connector the positive boom switch wire is connected to triggers the driver
when in manual mode.
FIGURE 7. Boom Switch Wires Disconnected
Parallel Positive
Boom Switch
Wire and
Console Wire
4. Disconnect the parallel positive and negative boom switch wires from the bottom of the switch.
IMPORTANT:
When connecting the boom valve connections, refer to Table 1 below if the machine has three boom
sections, and Table 2 for five boom sections.
Manual No. 016-0171-079 Rev F
ACCUBOOM INSTALLATION
Negative Boom
Switch Wire
11