MAINTENANCE
SECTION 8
Page
9
FUSES
AI R-CONDITIONER (If equipped)
There are two fuses located behind the L.H. outside filter.
Refer to item 2, IIlust. 5. Each of the fuses protects one of
the air- conditioner fan motors. The fuses are 14- amp
capacity. There is also a fuse in the instrument panel
protecting the entire air-conditioning circuit. Refer to Illust.
1
in Section
3.
Referto HELECTRICAL SYSTEM" in Section
8
for addition-
al information on fuses.
AIR PRESSURESYSTEM
The air compressor governor is factory set to maintain a
minimum pressure of 105 psi and a maximum pressure of
125 psi in the air system. If the air compressorgovernor does
not cut out when maximum governor pressureis reached,the
air tank safety valve will open at the factory setting of 150
psi.
If the governor and/or the safety valve fails to operate
properly, consult your authorized International Construction
Equipment distributor or dealer.
DRAINING THE AIR TANKS
S UPPLY
CAUTION:
COMPLETELY
LOWER THE
BUCKET TO PREVENT VEHICLE MOVE-
MENT. BE SURE THERE IS AN ADEQUATE
OF PRESSURE IN THE AIR SYSTEM.
NOTE: It is especially important that the air tanks are
thoroughly drained of water in cold weather.
lIIust. 11
Air Tank Drain Valves.
CAUTION:
DO NOT OPEN THE DRAIN
VALVES MORE THAN TWO TURNS.
Open the air tank drain valves (1 and 2, Illust. 11). Drain
accumulated water from the tanks and then closethe valves.