International H-400C Operator's Manual page 55

Pay loader
Table of Contents

Advertisement

SECTION 7
SCHEDULED
MAINTENANCE
4)
Page
10
SERVICE POINTS
Item
12 -
Parking Brake Actuators Fluid Level
(lliust.
4)
.
lIIust.4
Parking Brake Actuator Filler Cap.
There are two parking brake actuators. They are located in
the front frame below the steering cylinders and in front of
the parking brake unit.
1. Clean the area around the filler cap, then remove the cap.
2. Check the fluid level (the correct level is 3/4 inch from the
top of the filler neck). If necessary,add fluid. Refer to
"LUBRICANT
SPECIFICATIONS AND CAPACITIES" in
this section for the type of lubricant specified.
3. Before installing the filler cap, be sure the vent hole in the
filler cap is not pluggedup.
4. Install and securethe cap.
Item 13 - Axle Lubricant (Illust. 5)
Checking Lubricant Level
lIIust. 5
Axle Lubricant Level Check Plug.
1. Position the machine on level ground so the check plug (1)
is either left or right on the axle horizontal center line. Refer
to IIlust. 5. Let the machine sit long enough for the oil to
level out in the planetaries and housing.
2. Cleanthe areaaround the check plug. Removethe plug (1)
and check the lubricant level. The lubricant must be level
with the bottom of the check hole.
3. If the level is low, remove the fill plug from the center
of the axle bowl. Add lubricant through fill hole in the
axle bowl until it starts flowing from the check plug (1,
IIlust. 5). Refer to "LUBRICANT SPECIFICATIONS AND
CAPACITIES" in this section for the type of lubricant
specified.
4. Install the fill and check plugs.
5. Repeatthe above procedure on the secondaxle.
~;
.... ~
.,