International H-400C Operator's Manual page 20

Pay loader
Table of Contents

Advertisement

INSTRUMENTS
AND
CONTROLS
SECTION 3
Air CleanerService Indicators (lliust. 9)
There is an air cleaner serviceindicator mounted on the tube
between each air cleaner and the engine. During operation
the red band will gradually rise in the indicator window (A)
as dirt accumulates in the air filter elements. THIS MUST
NOT BE MISTAKEN AS A SIGNAL FOR ELEMENT
SERVICE. When the filter elements reach the maximum
allowable restriction, the red band will completely fill the
indicator window and automatically lock in this position.
The red band will remain fully exposed even after stopping
the engine. When this happens, filter element service is
required. For air cleaner service instructions, refer to "AIR
CLEANING SYSTEM" in Section 8.
Pressthe reset button (B) on the indicator after the elements
are serviced.
lIIust. 9
Air CleanerService Indicator .
Page9
Electrical System Master Switch
The electrical system master switch (Illust. 10) is usedto cut
off the flow of electrical current to all machine systems.
CAUTION:
THE ELECTRICAL
SYSTEM
MASTER SWITCH SHOULD BE TURNED
OFF (NO CURRENT) WHENEVER THE
ELECTRICAL
SYSTEM IS BEING WORKED ON.
To turn the electric current off, turn the key and remove it.
NOTE: Keep the switch turned "ON" while the engine
is running.
lIIust. 10
Electrical System Master Switch.