Chapter 1
General Troubleshooting
l.
m.
Confirm that the newly created circuit appears on the Circuits tab and that the Dir column describes it
Step 4
as a one-way circuit.
Complete the
Step 5
Test and Delete the Electrical Port Hairpin Circuit
Step 1
If the test set is not already sending traffic, send test traffic on the loopback circuit.
Examine the test traffic received by the test set. Look for errors or any other signal information that the
Step 2
test set is capable of indicating.
Step 3
If the test set indicates a good circuit, no further testing is necessary with the hairpin circuit. Clear the
hairpin circuit:
a.
b.
c.
d.
e.
Complete the
Step 4
Test the Standby XC-VXL Cross-Connect Card
Two XC-VXL cross-connect cards (active and standby) must be in use on a node to use this procedure.
Note
Perform a reset on the standby cross-connect card to make it the active card:
Step 1
a.
b.
c.
d.
July 2005
If the VC Optimization dialog box is displayed, leave all defaults.
Click Finish.
"Test and Delete the Electrical Port Hairpin Circuit" procedure on page
Click the Circuits tab.
Choose the hairpin circuit being tested.
Click Delete.
Click Yes in the Delete Circuits dialog box. Do not check any check boxes.
Confirm that the hairpin circuit is deleted form the Circuits tab list.
"Test the Standby XC-VXL Cross-Connect Card" procedure on page
Determine the standby cross-connect card. On both the physical node and the CTC node view
window, the standby cross connect ACT/STBY LED is amber and the active card ACT/STBY LED
is green.
Position the cursor over the standby cross-connect card.
Right-click and choose RESET CARD.
Click Yes in the confirmation dialog box.
1.2.2 Perform a Hairpin Test on a Source-Node Electrical Port (West to East)
Cisco ONS 15454 SDH Troubleshooting Guide, R5.0
1-15.
1-15.
1-15