Analog Interface Programming

6
Analog Interface Programming
Programming of the inclination sensor via analog interface is an alternative to RS-232
programming. Note that only some functions can be SET via analog inputs SET 1 and SET 2.
The following functions can be SET via analog inputs SET 1 and SET 2. Before analog
programming, the analog functions must first be set via RS-232 interface to implement this
function.
Analog output scaling to set the measuring range
• The inclination sensor must first be set to teach-in mode (teach 1) via RS-232
Inversion of measurement direction
• The inclination sensor must first be set to the preset/direction mode (teach 0), and
Preset of origin - 0° as reference for measurement
• The inclination sensor must be set to the preset/direction mode (teach 0) via RS-232
6.1

Electrical Connection and Programming

The sensors are connected via a M12 x 1, 8-pin, male connector. For programming via analog
interface, only pins 1, 4, 6, 8 are relevant. The other pins do not need to be connected.
Signal
+U
b
GND
Analog output x-axis
SET 1 (analog input 1)
Analog output y-axis
SET 2 (analog input 2)
Pinout
Table 6.1
24
interface.
the "compl" function must be set to parameter 2 (compl 2) via RS-232 interface.
interface. Preset/direction mode is the default factory setting. With a 2-axis sensor,
the preset function is applied to both axes simultaneously. There is no separate
preset function for each axis.
INX***DH-F199-IE2-***
Pin
1
4
5
6
7 (static 2.2 mA, INX* has no Y-
axis)
8
INy***DH-F199-IE2-***
Pin
1
4
5
6
7
8
1
8
7
2
6
3
5
4
1
8
7
2
6
3
5
4