Firmware Features Overview
4.3

Programmable Parameters

The parameter settings of INX***DH-F199-IE2-*** and INY***DH-F199-IE2-*** series
inclination sensors can be programmed via the RS-232 interface. Additionally, a few of these
functionalities are also available through analog inputs SET1 and SET2.
Configuration mode
Baud rate
Output transmission rate
Moving average filter
Preset value
Measurement direction
Analog output scaling
Table 4.2
Inclination sensor can be
switched between preset
/direction mode and teach-in
mode
The baud rate can be
programmed between ranges of
2400 bps and 115200 bps
The transmission rate of angular
values can be adjusted between
62.5 ms and 10 s per value
Used to calculate the output
position value as an average
over last N values where N
varies from 1 to 256
measurements (where N = 2n, n
= 0, 1, 2, 3
)
The current position value is set
to the mid angle and zero
position by the parameter
preset.
The direction of measurement
can be inversed according to the
measurement requirement
The analog output (4 ... 20 mA)
can be scaled to the required
measuring range. The default
ranges are 0° to 359.99°.
Programmable via
RS-232
RS-232
RS-232
RS-232
RS-232 and analog input1:
SET1*
*: only in preset/direction
mode
RS-232 and analog input2:
SET2*
*: only in preset/direction
mode
RS-232 and analog inputs1
and 2: SET1 and SET2*
*: only in teach-in mode
15