Retrieving A Setting; Configuration Mode; Baud Rate - Pepperl+Fuchs INX DH-F199-IE2 Series Manual

With analog interface and rs232 programming interface
Table of Contents

Advertisement

INX***DH-F199-IE2-***, INY***DH-F199-IE2-***
RS232 Interface Setup and Programming
Teach-in Mode Commands
Function
Set maximum V/I at current position
Reset the maximum V/I to factory default
position
Table 5.2
5.3.1

Retrieving a Setting

Function
Description
Retrieving a
Typing a command
parameter
with a question mark
setting
(?) at the end (without
space) will retrieve
the current setting.
Table 5.3
5.3.2

Configuration Mode

Function
Description
Configuration
Switch between
modes
preset/direction
mode and teach-in
mode for scaling
Table 5.4
5.3.3

Baud Rate

Note!
Baud Rate
We recommend accepting the default factory baud rate. If the user forgets the adjusted baud
rate, the new value has to be determined by testing. Resetting the baud rate to the default value
is not possible.
Function
Description
Baud rate
Switch between
different baud rates
Table 5.5
Command
setmax<CR>
clrmax<CR>
Command
Explanation
Example:
You can retrieve any parameter
period?
by typing the appropriate
Period 2: 100 ms OK
command.
Command
Explanation
teach<SP>0<CR>
When using the RS-232 and
analog interfaces simultaneously,
for preset/direction
take appropriate precautions.
mode (teach 0)
Be careful not to mix up the
teach<SP>1<CR>
commands for the RS-232 teach-
in modes. If in doubt, use the
for teach-in mode
restore command and
(teach 1)
reconfigure sensor.
The configuration/scaling set in
teach 1 mode is not reflected in
teach 0 mode.
Command
baud<SP>parameter<CR>
Parameters
Parameters
0 = 2400 bps
1 = 4800 bps
2 = 9600 bps
3 = 19200 bps
4 = 38400 bps
5 = 57600 bps
6 = 115200 bps
Default
Default
Preset/Direc
tion mode
(teach 0)
Default
9600 bps
21