INX***DH-F199-IE2-***, INY***DH-F199-IE2-***
RS232 Interface Setup and Programming
5.3.8
Measurement Direction
Function
Description
Measurement
Inverts measurement
Direction
direction.
Note: Before using
the command, ensure
that the sensor is set
to "teach 0".
Table 5.10
5.3.9
Set Maximum
Function
Description
Set maximum
The current angle
at current
position is set to the
position
maximum analog
output value.
Note: Before using
the command, ensure
that the sensor is set
to "teach 0".
Table 5.11
5.3.10
Reset Maximum
Function
Description
Reset
The execution of this
maximum to
function clears the
factory settings
previous scaling of
maximum set by the
user and resets the
analog output to the
factory default values.
Before using this
command, ensure
sensor is set into
"teach 1"
Table 5.12
5.3.11
Restore Factory Settings
Function
Description
Restore factory
Restore factory
settings
settings
Table 5.13
5.3.12
Save Settings to EEPROM
Function
Description
Save Settings
All settings that are
to EEPROM
modified will be
saved in the
EEPROM
Table 5.14
Command
compl<SP>parameter<CR>
Command
Explanation
setmax<CR>
The command execution
immediately sets the analog
output to 20 mA.
The maximum angle set in this
mode will not affect the RS-232
position output. This scaling only
affects the analog output.
Command
Explanation
clrmax<CR>
The command execution
immediately sets the analog
output to 20 mA.
Command
Explanation
restore<CR>
–
Command
Explanation
save<CR>
In case of changing the baud
rate, the new baud rate will be
active directly after a <CR>, a
"save" command is not required.
Parameters
0 = clockwise only
1 = counterclockwise
= SET 2 acitvate
(change only via anlog
inputs: L = clockwise,
H = counterclockwise)
Default
0
Default
–
Default
–
Default
–
Default
–
23