INX***DH-F199-IE2-***, INY***DH-F199-IE2-***
RS232 Interface Setup and Programming
5.3.4
Output Transmission Rate
Function
Description
Output
The transmission rate
transmission
of angular values can
rate
be adjusted.
Table 5.6
5.3.5
Moving Average Filter
The moving average filter length accepts only 2
max. length is 256. If the input number is not a 2
n
2
number will be taken. E. g. input = 14 will be rounded to 8, Input =18 will be rounded to 16
etc.
Function
Description
Moving
Used to calculate the
Average Filter
output position value
as an average over
last N values
Table 5.7
5.3.6
Preset Value
Function
Description
Preset Value
The current position
value is set to the mid
angle (2-axis) and
zero position (1-axis)
by the parameter
preset.
Table 5.8
5.3.7
Restore Origin
Function
Description
Reset the origin
The origin position
to factory
can be reset to
default position
factory default
position by using this
command. The
analog output is also
reset to show the
factory default output.
Table 5.9
22
Command
period<SP>parameter<CR> Parameters
n
values such as 4, 8, 16, 32 ... etc. and the
n
number from 4, 8, 16, 32 ... etc, the next lower
Command
filter<SP>parameter<CR> N varies from 1 ... 256
Command
Explanation
setorg<CR>
The analog output is also reset to
read 4 mA.
The use of preset in the digital
interface will affect the analog
output too.
Command
Explanation
clrorg<CR>
–
Parameters
1 = 62.5 ms
1 = 100 ms
2 = 200 ms
3 = 500 ms
4 = 1000 ms
5 = 5000 ms
6 = 10000 ms
Parameters
measurements
Default
100 ms
Default
64
Default
–
Default
–