Programming Commands In Configuration Mode - Pepperl+Fuchs INX DH-F199-IE2 Series Manual

With analog interface and rs232 programming interface
Table of Contents

Advertisement

INX***DH-F199-IE2-***, INY***DH-F199-IE2-***
RS232 Interface Setup and Programming
5.3

Programming Commands in Configuration Mode

The following table displays all programmable parameters via RS232 interface. Additionally, a
few of these functionalities are programmable via analog interface.
Note!
Baud Rate
Resetting the baud rate to the default value is not possible. If the user forgets the adjusted baud
rate, testing must be done to determine the new value.
Note!
General Information and Command Suffixes
Using the preset in the digital interface also affects the analog output. If both interfaces are
used simultaneously, appropriate precautions must be taken. Be careful not to mix up the
commands for the RS-232 teach-in modes. If in doubt, use the restore command and
reconfigure sensor. The configurations/scaling set in teach 1 mode is not reflected in teach 0
mode.
When parameters are defined beyond the programmable limits, the inclination sensor gives an
error "E" output.
Generally a space <SP> should sepLarate a command from a parameter.
Every command is terminated by <CR> (press Enter button).
Typing a command with a question mark <?> at the end without <SP> will return the current
setting information.
General Commands
General Functions
Enter configuration mode
Leave configuration mode
List of commands
Identity and versions
Parameter info
Current position value
Configuration modes
Baud rate
Output transmission rate
Moving average filter
Preset value
Measurement direction
Set maximum at current position
Reset maximum to factory settings
Restore factory settings
Reset the origin to factory default position
Software reset
Save settings to EEPROM
Table 5.1
20
Command
<CR>
exit<CR>
help<CR>
*idn<CR>
info<CR>
teach<SP>parameter<CR>
teach<SP>parameter<CR>
baud<SP>parameter<CR>
period<SP>parameter<CR>
filter<SP>parameter<CR>
setorg<CR>
compl<SP>parameter<CR>
setmax<CR>
clrmax<CR>
restore<CR>
clrorg<CR>
*rst<CR>
save<CR>