EMC VPLEX Installation And Setup Manual page 74

With geosynchrony 4.1
Table of Contents

Advertisement

Setting up VPLEX
Name
------------
UNREGISTERED-0x10000000c866fff2
UNREGISTERED-0x10000000c866fff3
UNREGISTERED-0x10000000c866ffec
UNREGISTERED-0x10000000c866ffed
74
EMC VPLEX with GeoSynchrony 4.1 Installation and Setup Guide
Output example (partial):
port-wwn
------------------
0x10000000c866fff2
0x10000000c866fff3
0x10000000c866ffec
0x10000000c866ffed
8. Type the following commands to register each initiator port:
cd /clusters/cluster-<Cluster_ID>/exports/initiator-ports
export initiator-port register -i <initiator_port> -p
<portWWN|nodeWWN>
9. Type the following commands to create and export the storage view:
cd /clusters/cluster-<Cluster_ID>/exports
storage-view create -c /clusters/cluster-<Cluster_ID>/ -n
<storage_view_name> -p <VPLEX_port>,<VPLEX_port>
10. Type the following commands to add each initiator port to the storage view:
cd /clusters/cluster-<Cluster_ID>/exports
storage-view addinitiatorport -v <storage_view_name> -i
<initiator_port>,<initiator_port>
11. Type the following commands to add the virtual volume(s) to the storage view:
cd /clusters/cluster-<Cluster_ID>/exports
storage-view addvirtualvolume -v <storage_view_name> -o
<virtual-volume_name>
Note that for any virtual volumes you add after the first one, you must add -f to
the end of the command. For example:
storage-view addvirtualvolume -f -v <storage_view_name> -i
<virtual-volume_name>,<virtual-volume_name>
Note: Including -f forces the virtual volumes to be added to the view even if the specified
LUNs are in use, the view is live, the virtual volumes are already assigned to another view,
or there are problems determining the view's state.
12. Type the following commands to verify the status of the storage view:
cd /clusters/cluster-<Cluster_ID>/exports/storage-views
export storage-view summary
node-wwn
type
------------------ -------
0x20000000c866fff2 default
0x20000000c866fff3
default
0x20000000c866ffec
default
0x20000000c866ffed
default
Target Port Names
--------------------------
P000000003CA00165-A0-FC00,
P000000003CA00183-A0-FC00,
P000000003CB00165-B0-FC00,
P000000003CB00183-B0-FC00
P000000003CA00165-A0-FC01,
P000000003CA00183-A0-FC01,
P000000003CB00165-B0-FC01
P000000003CA00165-A1-FC00,
P000000003CA00183-A1-FC01,
P000000003CB00165-B1-FC00,
P000000003CB00183-B1-FC01
P000000003CA00165-A0-FC01,
P000000003CA00183-A1-FC00,
P000000003CB00165-B0-FC01,
P000000003CB00183-B0-FC01,
P000000003CB00183-B1-FC00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents