ME96 QUICK START MANUAL

3.2 MOUNTING INSTRUCTIONS

Review Package Contents
Part Name
Quantity
Attachment lug
2
(with screw)
n DIMENSION OF PANEL
Panel hole dimensions are as shown in the following figure. It can be
attached to a panel with thickness of 1.6 to 4.0mm.
n VIEW ANGLE
+ 0.5
92
0
The contrast of the display changes at view angle. Mount it at the
position that is easy to see.
Viewing angle
10°
60°
(side view)
n ATTACHMENT
For attachment of the basic device into the panel hole, attach
according to the following procedure.
NOTE: The attachment lug is installed in two holes of the top and
bottom of the basic device. Tighten the screws of the lug, and fix
onto the panel. To prevent damage to the panel and screws, do not
fasten screws too tightly. Recommended torque for these products:
0.3~0.5N·m (approx. half of standard torque) Also, please tighten the
upper and lower screws at the same time.
6
Mitsubishi Electric Automation, Inc.
Specifications
(overhead view)

4. SPECIFICATIONS AND WIRING

CAUTION
MAINTENANCE INSTRUCTIONS
• Do not connect with hot-line
• Do not use in the condition that the secondary circuit of CT is
opened.
• Do not use in the condition that the secondary circuit of VT is
short-circuited.
• The wire size has to be suited for the rated current and rated voltage.
Terminals of +C1, C1, +C2, C2, +C3, C3: AWG24 to 14 (For UL
recognized: Single wire of AWG22 to 16)
• Terminals of instrument main body (except for +C1, C1, +C2, C2,
+C3, C3 terminals): AWG24 to 14 (For UL recognized: AWG24 to
18). When using a stranded wire, use a ferrule.

4.1 WIRING

Insert hole
1. Remove the wire casing at the end of the wire and solder to the rod
terminal.
2. With the lever pushed in, insert the wire and then release the lever
to connect.
Confirmations
After wiring, make sure the following:
• All wiring is connected
• There is no mistake in wiring
PROTECTIVE SHEET
There is a protective sheet covering the LCD screen to prevent
scratching during panel installation. Please remove the sheet before
using the meter. When removing the sheet, the LCD may turn on due
to the static electricity generated. This is not abnormal; the LCD will
turn off after a short time.
INSTALLATION POSITION
If installing the unit at the panel edge, choose an installation position
where there is sufficient space for wiring work.
Lever