How to Install

7.2.1. Mounting Hole Dimensions

The right figure shows the hole drilling dimensions of the panel.
Use a panel with a thickness of 1.6 mm to 4.0 mm for installation.

7.2.2. Mounting Position

The contrast of LCD display changes depending on the angle of view.
Install the instrument in a location where you can easily see it.
View from the side

7.2.3. Mounting and Fixing

You will install the instrument on a panel according to the following procedure.
①Install the two attachment lugs on the top and bottom
of the unit.

7.2.4. Optional Plug-in Module Installation

You will install the optional plug-in module to the instrument according to the following procedure.
①Remove the option cover.
The protection sheet is attached to the LCD display to prevent scratches on the display
during installation. Before starting operation, remove the sheet. When you remove the
sheet, the LCD display may light up due to static electricity generation. However, this is not
abnormal. After a while, the lighting goes off due to self-discharge.
Note
When you install the instrument on the edge of the panel, check the work space for wiring
to determine the mounting position.
Before installing the optional plug-in module, turn off the power supply of auxiliary power.
If you install it under power distribution, the instrument will not recognize it.
In this case, you should get auxiliary power distribution/recovery or restart the instrument
and then the instrument will recognize the optional plug-in module.
View from the top
②Tighten the screws of the attachment lugs
to fix them to the panel.
②Install the optional plug-in module to the unit.
Protection sheet
Mounting position
Optional plug-in module
104
Hole drilling dimensions of
the panel
The mounting screw type: M3
To prevent damage to the
panel and screws, do not
overtighten the screws.
Tighten the two screws evenly.
Note
The recommended torque for
this product is 0.3 N•m to 0.5
N•m (about half the normal
torque).
The tongue of the optional
plug-in module is fitted into
the groove of the unit.