Printhead Adjustment; Setting The Head Aperture - Avery Dennison 64 Series Service Manual

Dispenser
Table of Contents

Advertisement

03/10 Rev. 5.04-04

Printhead adjustment

Adjusting the head aperture
When switched on and with ribbon, the aperture
between the thermal head and feed roller can
measure between 0.75 mm and 1.00 mm.
If this is not the case, set the head aperture as
follows:
Tools
Allen keys 1.5 and 3 mm
Preparation
1. Remove rear hood and left front housing.
2. Remove display from the left front housing;
leave the connection cable plugged in.
For instructions refer to paragraph
on page 6.
3. Set the print head contact pressure to the
minimum.
4. Insert ribbon and thin material.
SERVICE FUNCTIONS >
5. Call parameter
Head adjust.
Confirm by pressing the Enter
button.
Head adjust
Press Feed key
STOP! Don´t press the Feed key yet!
6. Loosen the head lever fixing screw (1).
7. Unscrew the oscillator disc (2) setting
screw (3).
For better visibility, the illustrations show
the parts disassembled.
Continued next page
SERVICE MANUAL
64-xx – 64-xx Dispenser
Housing
Service Mechanics
1
2
3