Ribbon core brake

The clamping of the paper core on the ribbon
unwinding core and the ribbon roll-up core can
be adjusted by setting the spring plate.
Setting:
1. Unscrewing the Phillips screws (1).
2. Setting of the securing plate (2) to the
required core diameter.
3. Fixing with the Phillips screws.
If one of the threads is stripped, move the
spring plate along the axis and reaffix it.
Tool
– Phillips size 1

Ribbon guide

The ribbon guide mandrel is for the non-
contact feeding of the ribbon to the thermal
bar.
Disassembling/assembly
1. Unscrewing the fastening screw in the
cast block.
2. Remove the guide mandrel (1) to the
front.
Tool
– Socket wrench SW 10