Punch Sensor - Avery Dennison 64 Series Service Manual

Dispenser
Table of Contents

Advertisement

03/10 Rev. 5.04-04

Punch sensor

The punch sensor (1) recognises the
beginning or end of a label.
Varying forms of labels (e. g square or round),
different materials (e. g. card or self-adhesive
material), as well as different requirements
(e. g. transparency or reflex), require the use
of variably adjustable photoelectric switch.
A multitude of material properties (e. g. light
transparency) place extra demands on the
setting capabilities of the punch sensor.
Standard sensor: Transparency
Optional sensor: Reflex
The punch sensor can be moved at right
angles to the feed direction using an
adjustment knob which is accessed from
outside of the device.
Disassembling
1. Unscrew the Phillips screw (2) in the
setting knob.
2. Remove the rear hood.
3. Remove the ratchet wheels (3) of the
feed rollers 1 and 2.
Details can be found in paragraph
rollers
on page 35.
4. Remove the sensor mechanism (4) to
the rear and replace if necessary.
Assembly
1. Grease the sides of the photoelectric
switch mechanism and reinsert it.
2. Tighten the setting knob with a Phillips
screw (pay attention to the zero
position).
3. Mount the ratchet wheels of the feed
rollers
4. Check that the photoelectric switch
mechanism moves easily.
Tool
– Phillips screwdriver size 1
SERVICE MANUAL