Beater Rotation; Refrigerant - Taylor 432 Operator's Manual

Frozen beverage unit with raised drip tray
Hide thumbs Also See for 432:
Table of Contents

Advertisement

Beater Rotation

NOTICE! Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
Note:
The following procedures must be performed by
a Taylor service technician.
To correct rotation on a single-phase machine, change
the leads inside the beater motor. (Follow the diagram
printed on the motor.)

Refrigerant

CAUTION! This machine contains fluorinated
greenhouse gases (F-Gas) to provide refrigeration using
a hermetically sealed circuit or within foam insulation.
This unit's type of gas, quantity, Global Warming
Potential (GWP) and CO
2
is recorded on the machine's data label. The refrigerant
used is generally considered non-toxic and non-
flammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
CAUTION! Use only approved refrigerant
listed on the machine's data label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards.
To the Installer
tonnes equivalent information
WARNING! Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush immediately with cold water. If burns are severe,
apply ice packs and contact a physician immediately.
NOTICE! Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
IMPORTANT! Refrigerants and their
associated lubricants may be extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Model 432
TO THE INSTALLER
1-3
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents