8 OPERATION CHECK OF SAFETY CIRCUITS
Installation of Safety
Light Curtain
7
8.1 Installation of Safety Light Curtain
Install the safety light curtain. For details, refer to the following.
deTec4 Safety light curtain OPERATING INSTRUCTIONS
8.2 Operation Check
8
Check the following operations after the packaging machine in the connection example of the safety devices
(
P. 9
) starts running.
• Entire stop
• Partial stop
Entire stop
Check that all the safety contactors turn OFF when the emergency stop pushbutton is pressed.
Step 1
. Pressing the emergency stop pushbutton
9
Press the emergency stop pushbutton. Check that all the safety contactors turn OFF and the entire packaging
machine stops. Check the ON/OFF status of the safety contactors with the contact carriers.
Step 2
. Resetting the emergency stop pushbutton
Reset the emergency stop pushbutton. The safety contactors remain OFF, indicating that the restart interlock
circuit is functioning.
Step 3
. Pressing the reset switches 1 and 2
After the entire packaging machine stops, press the reset switches 1 and 2 to turn ON the safety contactors
. Check that the restart interlock is released using the reset switches 1 and 2 and the packaging machine starts
4
running again.
Reset switch 1
Reset switch 2
32
Operation Check
• Reset interlock
ON
Safety
Safety
1
2
contactor
contactor
<Drive unit of the filling machine>
OFF
Safety
Safety
1
2
contactor
contactor
<Drive unit of the filling machine>
OFF
Safety
Safety
1
2
contactor
contactor
<Drive unit of the filling machine>
OFF
Safety
Safety
3
4
contactor
contactor
<Drive unit of the belt conveyor>
Safety
Safety
3
4
contactor
contactor
<Drive unit of the belt conveyor>
ON
Safety
Safety
3
4
contactor
contactor
<Drive unit of the belt conveyor>
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
to
1
OFF
ON
ON
OFF
ON
OFF