Table Of Contents; Panel Meter S40-T; How To Order - Fema S Series User Manual

Panel meter for temperature signals
Hide thumbs Also See for S Series:
Table of Contents

Advertisement

FEMA ELECTRÓNICA . Series S . S40-T

1. Panel meter S40-T

Panel meter in compact 72
Panel meter in compact 72 x 36 mm size, for temperature signals, with
14 mm digit height. Accepts signals from Pt100 / RTD (2 and 3 wires)
and thermocouples J, K, T, E, S, R, N, C, L and X. Configurable reading
in º Celsius or º Fahrenheit. Thermocouple cold junction compensa-
tion configurable (see section 1.11.2). Configurable offset for display
reading (see section 1.11.2). Selectable behavior in case of sensor
break (see section 1.11.2). Reading with 4 digits and negative sign.
Options for output and control with 1 and 2 relays, transistor out-
puts, controls for SSR relays, isolated analog outputs, communica-
tions in Modbus RTU, RS-485 ASCII and RS-232. Special options with
4 relay outputs.

1.1 How to order

Model
S40
-
T
Index
1. Panel meter S40-T . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 How to order . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Front view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Power connections . . . . . . . . . . . . . . . . . . . . . 3
1.5 Signal connections - Pt100 / RTD . . . . . . . . . . . . . 3
1.6 Signal connections - Thermocouple . . . . . . . . . . . . 3
1.7 Mechanical dimensions (mm) . . . . . . . . . . . . . . . 3
1.8 Technical specifications . . . . . . . . . . . . . . . . . . 4
1.9 Messages and errors . . . . . . . . . . . . . . . . . . . . 5
1.10 How to operate the menus . . . . . . . . . . . . . . . . 6
1.11 Configuration menu. . . . . . . . . . . . . . . . . . . . 7
1.11.1 Initial set-up . . . . . . . . . . . . . . . . . . . . . . 7
1.11.2 Temperature configuration . . . . . . . . . . . . . . 7
1.11.3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.11.4 Display filters. . . . . . . . . . . . . . . . . . . . . . 9
1.11.5 Fast access . . . . . . . . . . . . . . . . . . . . . . . 9
1.11.6 Super fast access . . . . . . . . . . . . . . . . . . . 9
1.11.7 Menu 'On Power Up' . . . . . . . . . . . . . . . . . 10
1.11.8 Menu 'Key LE' . . . . . . . . . . . . . . . . . . . . . 10
1.11.9 Function 'Password' . . . . . . . . . . . . . . . . . 10
1.11.10 Factory reset . . . . . . . . . . . . . . . . . . . . . 10
2
x
36
mm size for temperature signals
Power
-
H
-
-H
-R1
(85-265 Vac/dc)
-L
-AO
(11/60 Vdc,
24 Vac, 48 Vac)
-RTU
-S4
-S2
-T1
-SSR
-
Independent alarms configurable as maximum or minimum, with 1
or 2 setpoints per alarm, hysteresis, independent activation and de-
activation delays and control for inverted relay.
Front protection IP54. Connections by plug-in screw terminals. For
industrial applications.
• 'Fast access' menu to selected functions, accessible with key UP (5)
(see section 1.11.5)
• 'On power up' for system protection on first 'cold' start-up (see
section 1.11.7)
Display filters, memory for maximum and minimum reading, pass-
word protection, 5 brightness levels.
Option 1
Option 2
-
(1 relay)
(analog output)
(Modbus RTU)
(RS-485)
(RS-232)
(1 transistor)
(1 control SSR)
(empty)
1.11.11 Firmware version. . . . . . . . . . . . . . . . . . . 11
1.11.12 Brightness . . . . . . . . . . . . . . . . . . . . . . 11
1.11.13 Access to optional modules . . . . . . . . . . . . . 11
1.12 Full configuration menu . . . . . . . . . . . . . . . . . 12
1.13 To access the instrument . . . . . . . . . . . . . . . . . 14
1.14 Modular system . . . . . . . . . . . . . . . . . . . . . . 14
1.15 Precautions on installation . . . . . . . . . . . . . . . . 15
1.16 Factory configuration . . . . . . . . . . . . . . . . . . . 15
1.17 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.18 CE declaration of conformity . . . . . . . . . . . . . . . 15
2. Output and control modules . . . . . . . . . . . . . . . . . 16
2.1 Module R1. . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.2 Module T1. . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.3 Module SSR . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.4 Module AO . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.5 Module RTU . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.6 Module S4 . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.7 Module S2 . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.8 Modules R2, R4 . . . . . . . . . . . . . . . . . . . . . . . 19
Others
-
-G
(green led)

Advertisement

Table of Contents
loading

This manual is also suitable for:

S40-t

Table of Contents