Fema M40-D User Manual

Series m40 panel meter 96x48mm dc voltages dc currents

Advertisement

Quick Links

Series M40
Panel Meters
Model M40-D
Panel meter for DC voltages and DC currents. Measure category in CAT-III up to 300Vdc
and CAT-II up to 600Vdc. Current signal ranges for 5Adc and 1Adc. Housing 96x48mm
DIN standard. Display in 4 or 5 digits. Maximum and minimum display memory, scalable
reading, filters, steps, signal autocorrection, "measure" function, peak&hold, alarms with
double setpoints, 5 levels of brightness, ... Universal AC and DC power modules and up
to 3 modules for signal retransmission and control.
USER'S MANUAL
(2149R01)
Panel meter 96x48mm
DC voltages
DC currents

Advertisement

Table of Contents
loading

Summary of Contents for Fema M40-D

  • Page 1 Series M40 Panel Meters Panel meter 96x48mm Model M40-D DC voltages DC currents Panel meter for DC voltages and DC currents. Measure category in CAT-III up to 300Vdc and CAT-II up to 600Vdc. Current signal ranges for 5Adc and 1Adc. Housing 96x48mm DIN standard.
  • Page 2: Order Reference

    Using the instrument in ways not specified by the manufacturer may lead carbonic snow, never with water. to a reduction on the specified protection level. Disconnect the instrument from power before starting any maintenance and / or installation action. FEMA ELECTRÓNICA - Page 2...
  • Page 3: Front View

    Fuse - To comply with security regulation 61010-1, add to the power line a protection fuse acting as disconnection element, easily accessible to the operator and identified as a protection device. Power “H” fuse 250mA time-lag Power “L” fuse 400mA time-lag FEMA ELECTRÓNICA - Page 3...
  • Page 4: Technical Data

    ±1 Vdc 0.10% FS 65Vdc permanent ±100 mVdc 0.10% FS 4.5Vdc permanent ±5 Adc 0.15% FS 20mOhm 16Adc @5 sec. ±1 Adc 0.15% FS 20mOhm 16Adc @5 sec. Table 3 - Input signal range specifications FEMA ELECTRÓNICA - Page 4...
  • Page 5: Mechanical Dimensions (Mm)

    OptionX (OptX) - Type of module installed. If there is no module shows “nonE”. Measure Signal range Measured value Measure (MEAS)- Multimeter function. Shows the value of the input signal without scaling. This is the real value the instrument is receiving on signal terminals. FEMA ELECTRÓNICA - Page 5...
  • Page 6: Configuration Menu

    Alarm as min. Min= Minimum Setpoint2 Display Fixed digits Average Steps Setpoint Left zeros Counts Add zero to the right Memory of maximum -9999 Hysteresis Memory of minimum 9999 Seconds Peak & Hold Tools Delay Password Brightness FEMA ELECTRÓNICA - Page 6...
  • Page 7 Configuration for Option3 With left zeros Option3 Left Zeros Without left zeros Add zero XXXX0 Add Right Zero Not add XXXX Memory of maxim. Maximum Reset of maxim. Memory of minim. Minimum Reset of minim. FEMA ELECTRÓNICA - Page 7...
  • Page 8: Input Menu

    (dP), modification of the linear- maximum are deactivated when the display is lower than ization segments, or instrument power-down. the setpoint. The alarms configured as minimum have the inverse behavior. FEMA ELECTRÓNICA - Page 8...
  • Page 9: Tools Menu

    Options Menu Menu options OPT1, OPT2 and OPT3 give access to the configuration menus of the installed options. The menu de- pends on the installed option. If there is no option installed the instrument shows “nonE”. FEMA ELECTRÓNICA - Page 9...
  • Page 10: Accessing The Instrument

    70% 25 cycle Criteria B Isolation Double 0% 250 cycle Criteria B Category CAT-III up to 300Vdc CAT-II up to 600Vdc Barberà del Vallès September 2011 Daniel Juncà - Quality Manager Emission rules 61000-6-4 Generic rules of emission FEMA ELECTRÓNICA - Page 10...
  • Page 11 User’s Manual M40-D FEMA ELECTRÓNICA - Page 11...
  • Page 12 Signal Converters Panel Meters 60&100mm digit & Isolators Standard 96x48mm www.fema.es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRÓNICA, S.A. Altimira 14 - Pol. Ind. Santiga E08210 Barberà del Vallès BARCELONA - SPAIN Tel. (+34) 93.729.6004 - www.fema.es Fax (+34) 93.729.6003 - info@fema.es...