Series M40 Panel Meters Panel meter 96x48mm Model M40-D DC voltages DC currents Panel meter for DC voltages and DC currents. Measure category in CAT-III up to 300Vdc and CAT-II up to 600Vdc. Current signal ranges for 5Adc and 1Adc. Housing 96x48mm DIN standard.
Using the instrument in ways not specified by the manufacturer may lead carbonic snow, never with water. to a reduction on the specified protection level. Disconnect the instrument from power before starting any maintenance and / or installation action. FEMA ELECTRÓNICA - Page 2...
Fuse - To comply with security regulation 61010-1, add to the power line a protection fuse acting as disconnection element, easily accessible to the operator and identified as a protection device. Power “H” fuse 250mA time-lag Power “L” fuse 400mA time-lag FEMA ELECTRÓNICA - Page 3...
OptionX (OptX) - Type of module installed. If there is no module shows “nonE”. Measure Signal range Measured value Measure (MEAS)- Multimeter function. Shows the value of the input signal without scaling. This is the real value the instrument is receiving on signal terminals. FEMA ELECTRÓNICA - Page 5...
Alarm as min. Min= Minimum Setpoint2 Display Fixed digits Average Steps Setpoint Left zeros Counts Add zero to the right Memory of maximum -9999 Hysteresis Memory of minimum 9999 Seconds Peak & Hold Tools Delay Password Brightness FEMA ELECTRÓNICA - Page 6...
Page 7
Configuration for Option3 With left zeros Option3 Left Zeros Without left zeros Add zero XXXX0 Add Right Zero Not add XXXX Memory of maxim. Maximum Reset of maxim. Memory of minim. Minimum Reset of minim. FEMA ELECTRÓNICA - Page 7...
(dP), modification of the linear- maximum are deactivated when the display is lower than ization segments, or instrument power-down. the setpoint. The alarms configured as minimum have the inverse behavior. FEMA ELECTRÓNICA - Page 8...
Options Menu Menu options OPT1, OPT2 and OPT3 give access to the configuration menus of the installed options. The menu de- pends on the installed option. If there is no option installed the instrument shows “nonE”. FEMA ELECTRÓNICA - Page 9...
70% 25 cycle Criteria B Isolation Double 0% 250 cycle Criteria B Category CAT-III up to 300Vdc CAT-II up to 600Vdc Barberà del Vallès September 2011 Daniel Juncà - Quality Manager Emission rules 61000-6-4 Generic rules of emission FEMA ELECTRÓNICA - Page 10...