FEMA ELECTRÓNICA . Series S . S40-T

2. Output and control modules

2.1 Module R1

The R1 module provides 1 relay output to to install at digital panel
meters from Series S, up to a maximum of 2 relays in a single meter.
Note : for more than 2 relays per instrument or larger relay density
per module, see special modules R2 and R4.
Configuration is performed from the frontal keypad of the meter, by
setting the parameters at the alarm menu. Check the parameters of
at the alarm menu for full information.
Relay with 3 contacts (common, normally open, normally closed)
with up to 250 Vac switching voltage and 8 A.
Modules R1 can be ordered pre-installed into a Series S digital panel
meter, or standalone for delayed installation, as they do not require
soldering or special configuration.
Type of relay
Current maximum
Voltage maximum*
Isolation
Type of terminal
Slots allowed
Terminal A
Terminal B
Terminal C
Opt.1
A B C
Signal
For more information : http://fema.es/docs/4254_SERIES_M-K-S_
OPTIONS_manual_i.pdf
16
3 contact relay (NC, NO, common)
8 A per relay (resistive load)
250 Vac continuous
3500 Veff
plug-in screw terminal, pitch 5.08 mm
'Opt.1', 'Opt.2'
Common
NO - Normally open
NC - Normally closed
Opt.2
A B C
Power

2.2 Module T1

The T1 module provides 1 transistor output to install at digital panel
meters from Series S, up to a maximum of 2 transistors in a single
meter.
Configuration is performed from the frontal keypad of the meter, by
setting the parameters at the alarm menu. Check the parameters of
at the alarm menu for full information.
Transistor output is optoisolated, provides 2 terminals for connec-
tion, and can switch up to 35 V and 50 mA.
Modules T1 can be ordered pre-installed into a Series S digital panel
meter, or standalone for delayed installation, as they do not require
soldering or special configuration.
Type of output
transistor
Max. voltage
35 Vdc
Max. current
50 mA
Isolation
3500 Veff
Type of terminal
plug-in screw terminal, pitch 5.08 mm
Slots allowed
'Opt.1', 'Opt.2'
Schematic for T1 output
Opt.1
A B C
Signal
For more information : http://fema.es/docs/4254_SERIES_M-K-S_
OPTIONS_manual_i.pdf
'B'
'A'
Opt.2
A B C
Power