Fema M Series User Manual

Panel meter for load cells
Hide thumbs Also See for M Series:

Advertisement

Series M . M60-LC
Panel meter for load cells
DIGITAL PANEL METERS
Digital panel meter for load cells. Provides excitation voltage to power up to 8 cells. Standard
96 x 48 mm size (1/8 DIN). Reading with 6 digit display. Accepts 4 and 6 wire load cells, includes 'sense'
function, fast access to alarm setpoints, tare and 'auto-tare' functions, 'on power up' functions, stabil-
ity alarms, configurable operator menu, configurable led brightness. Universal AC and DC power. Up
to 3 optional modules for output and control (relays, transistor, control SSR, analog outputs, Modbus
RTU communications, RS-485 ASCII, RS-232, ...)
4507r05
ELECTRONICS
FOR
PANEL METERS . SIGNAL CONVERTERS . LARGE DISPLAYS
Tel. (+34) 93.729.6004 info@fema.es
User's Manual
INDUSTRIAL
AUTOMATION
Kg
Weight
www.fema.es

Advertisement

Table of Contents
loading

Summary of Contents for Fema M Series

  • Page 1 Universal AC and DC power. Up to 3 optional modules for output and control (relays, transistor, control SSR, analog outputs, Modbus RTU communications, RS-485 ASCII, RS-232, ...) www.fema.es Tel. (+34) 93.729.6004 info@fema.es 4507r05...
  • Page 2: Panel Meter M60-Lc

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1. Panel meter M60-LC Panel meter for load cells, size 96 mm (1/8 DIN)       Digital panel meter, with 96 x 48 mm (1/8 DIN) size and 6 Front protection IP65. Connections by plug-in screw ter- digits with 14 mm digit height, for load cell signals.
  • Page 3: Table Of Contents

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.2 Index 1. Panel meter M60-LC ....2 1.12.16 ‘On power up’ configuration ..19 1.1 How to use this manual .
  • Page 4: Material Included

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.4 Material included 1.6 Front view The shipment includes : Alarms and ‘A’,‘B’ leds - 1 instrument M60-LC - 1 pack of orange power terminals - 1 pack of green signal terminals - 1 user’s manual...
  • Page 5: Signal And Power Connections

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.8 Signal and power connections 1 2 3 4 5 6 7 8 9 0 Vexc+ Sense+ Neutral AC / Negative DC Signal+ Not connected Signal- Phase AC / Positive DC Sense- Figure 3 - Power connections...
  • Page 6: Technical Specifications

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.9 Technical specifications Digits step response see Table 2 number of digits 0 % to 99 % signal 7 segments signal terminals plug-in screw terminals (pitch 3.81  m m) color red or green Power digit height 14 mm...
  • Page 7: Signal Ranges

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.9 Technical data (cont.) 1.9.4 Mechanical dimensions (mm (in)) 1.9.2 Signal ranges The instrument works with 6 internal signal ranges and the active range is automatically selected when the in- strument is started. The selection depends on the value of the two parameters : ‘Sensitivity’...
  • Page 8: Included Functions

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.10 Included functions 1.11 ‘Tare’ functions included Activate the tare function to force the instrument to take the Included functions Section actual signal as a ‘0’ weight. The tare function does not mod-...
  • Page 9: Configuration

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12 Configuration 1.12.1 How to operate the menus The instrument has two menus accessible to the user : leaves from the configuration menu. Then changes are ap- plied and the instrument is back to normal function. When ‘Configuration menu’...
  • Page 10: Initial Set-Up

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.2 Initial set-up Before starting to configure the instrument, identify the pa- correct the individual deviations of this particular load cell. rameters of the load cell, at the manufacturers datasheet (see For the empirical configuration you will need access to two Table 5).
  • Page 11: Initial Setup Menu

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.3 Initial setup menu At the initial set up of the instrument, first configure the Press ‘SQ’ (<) for 1 second to access the ‘con- figuration menu’. For a description on how to op- theoretical part of the load cell at the ‘Load cell param-...
  • Page 12: Function 'Auto-Tare

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.4 Function ‘auto-tare’ 1.12.6 Function ‘stock’ The ‘auto-tare’ function automatically activates the ‘tare’ The ‘Stock units’ (‘Stck’) function is provided to count large when the weight is removed from the load cell. The ‘auto- quantities of small units, in situations such as stock invento- tare’...
  • Page 13: Advanced Configuration Menu

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.7 Advanced configuration menu At the ‘Auto-tare’ (‘Aut.t’) menu configure the activation val- ue and stability values to control the automatic activation of the tare, when weight is removed from the cell. See section Advanced conf.
  • Page 14: Alarms

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.8 Alarms The instrument manages 3 independent internal alarms, each Reading one controlling the activation of an optional relay, transistor setpoint or SSR control output. These outputs are optional (see section hysteresis 2) and are installed at the free slots of the instrument (see section 1.18).
  • Page 15: Alarm Configuration

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.9 Alarm configuration Alarms 1, 2 and 3 are configured from menu ‘ALr1’, ‘ALr2’ or ‘ALr3’. See section 1.12.8 for additional information. Alarms • at the ‘Active’ (‘Act’) parameter select ‘on’ • at the ‘Type of alarm’ (‘TypE’) parameter, select ‘MAX’...
  • Page 16: Display Filters

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.10 Display filters The instrument provides several functions to act upon the reading in order to increase stability, reduce noise and adapt to particular needs. These functions are grouped under the Display Fixed digits Fix digits ‘Display’...
  • Page 17: Rear Controls

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.11 Rear controls The instrument provides a digital ‘on/off’ input at the rear terminals, referenced as ‘EK’ (see section 1.8). Assign func- tions to this terminal and activate these functions with a short...
  • Page 18: Fast Access

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.13 Fast access The ‘fast access’ is an operator configurable menu. When • access to maximum and minimum memories from the configured, the operator can access the most usual functions front key ‘UP’ (5) allows to visualize the values. To reset the with a single press of the front key ‘UP’...
  • Page 19: Fast Access' Configuration Menu

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.15 ‘Fast access’ configuration menu At the ‘Key UP (‘fast access’)’ (‘K.uP’) menu configure which functions and parameters will be accessible through the ‘fast access’ menu. Select ‘on’ to activate each function. See sec- Key UP Setpoint 1...
  • Page 20: Tools

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.12.17 Tools The ‘Tools’ (‘tooL’) menu groups functions with a variety of uses. at the ‘Password’ (‘PASS’) function define a 6 digit code to Tools Password • block access to the ‘configuration menu’. Activate the pass- word to prevent access to the instrument configuration by non authorized personnel.
  • Page 21 FEMA ELECTRÓNICA . SERIES M . M60-LC...
  • Page 22: Full Configuration Menu

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.13 Full configuration menu Press ‘SQ’ (<) for 1 second to access the ‘con- figuration menu’. Standard Mode 50 Hz Load cell Initial conf. 60 Hz Deci mal point parameters Nominal weight Sensitivity...
  • Page 23 FEMA ELECTRÓNICA . SERIES M . M60-LC Display Fixed digits Fix digits Key LE Tare Alarm unlock Average filter 0 to 100 Stock units Steps Left zeros Key UP Setpoint 1 (fast access) Memory of Setpoint 2 maximum Setpoint 3 Memory of minimum...
  • Page 24 FEMA ELECTRÓNICA . SERIES M . M60-LC 1.14 Full configuration menu (cont) On power-up Delay Seconds Tare Tools Password Factory configuration Reset ‘initial conf.’ Version Minimum Brightness Standard Maximum Access to the optional module installed at slot 1 Option 1 Access to the optional module installed at slot 2 Option 2...
  • Page 25: Factory Configuration

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.14 Factory configuration 1.15 Messages and errors Initial configuration (‘InIt’) Error messages are informed flashing on display. Load cell parameters (‘cELL’) Decimal point (‘dP’) without (XXXXXX) Sensitivity mV/C (‘MV.V’) 2.0000 Messages and errors Nominal weight(‘LoAd’)
  • Page 26: Practical Cases

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.16 Practical cases 1.16.1 Normal case 1.16.3 Connections with a junction box Case for 1 load cell, powered from the instrument, with A ‘junction box’ for load cells has internal elec- power 10 Vdc, nominal weight 100 Kg and 2 mV/V sensi- tronics that can modify the ‘signal / weight’...
  • Page 27: Connections With 3 Or 4 Load Cells

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.16 Practical cases (cont.) 1.16.4 Connections with 3 or 4 load cells 1.16.5 Measuring mV at the laboratory Using 3 load cells is the optimal way to distribute the If you wish to configure the instrument to measure a mil-...
  • Page 28: To Access The Instrument

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.17 To access the instrument To open the housing and access the internal circuits, use a flat screwdriver to unlock clips ‘D’, ‘C’, ‘B’ and ‘A’, in this order. Remove the front filter. Let the inside of the instru- ment slide out of the housing.
  • Page 29: Precautions On Installation

    FEMA ELECTRÓNICA . SERIES M . M60-LC 1.19 Precautions on installation 1.21 CE declaration of conformity Manufacturer FEMA ELECTRÓNICA, S.A. Risk of electrical shock. Instrument terminals Altimira 14 - Pol. Ind. Santiga can be connected to dangerous voltage. E08210 - Barberà del Vallès Instrument protected with double isolation.
  • Page 30: Output And Control Modules

    FEMA ELECTRÓNICA . SERIES M . M60-LC 2. Output and control modules 2.1 Module R1 2.2 Module T1 The R1 module provides 1 relay output, to install on Series The T1 module provides 1 transistor output, to install on Se-...
  • Page 31: Module Ssr

    FEMA ELECTRÓNICA . SERIES M . M60-LC 2.3 Module SSR 2.4 Module AO The SSR module provides 1 output to control an SSR relay, to The AO module provides 1 isolated analog output, configu- install on Series M meters, up to a maximum of 3 SSR outputs rable for 4/20 mA or 0/10 Vdc, to install on Series M me-...
  • Page 32: Module Rtu

    FEMA ELECTRÓNICA . SERIES M . M60-LC 2.5 Module RTU 2.6 Module S4 The RTU module provides 1 isolated RS-485 Modbus RTU out- The S4 module provides 1 isolated RS-485 ASCII output, to in- put, to install on Series M meters.
  • Page 33: Module S2

    FEMA ELECTRÓNICA . SERIES M . M60-LC 2.7 Module S2 2.8 Modules R2, R4, R6 The S2 module provides 1 isolated RS-232 ASCII output, to in- Special modules R2, R4 and R6 offer 2, 4 and 6 relay outputs, stall on Series M meters.
  • Page 34: Other Options

    FEMA ELECTRÓNICA . SERIES M . M60-LC 3. Other options 3.1 Option NBT 3.2 Option G Instruments without front key- Option with green leds pad. To configure the instru- ment, remove the meter from the panel and remove the front filter.
  • Page 35: Accessories

    FEMA ELECTRÓNICA . SERIES M . M60-LC 4. Accessories 4.1 THM benchtop housing 4.4 WME wall housing Benchtop housing for Se- Wall mount housing. To- ries M, K and C and of panel gether with the KIP protec- meters. Handle with three tor, offers a full IP65 pro- selectable positions.

This manual is also suitable for:

M60-lc

Table of Contents