Fema LP4 User Manual

Fema LP4 User Manual

Loop powered process meter

Advertisement

Quick Links

USER'S MANUAL
Model LP4
LOOP
POWERED
PROCESS METER
SERIES SPECIAL
www.fema.es
SPECIAL
mA
APPLICATIONS
Loop
YOUR METER  !
5137r01

Advertisement

Table of Contents
loading

Summary of Contents for Fema LP4

  • Page 1 USER’S MANUAL Model LP4 LOOP POWERED PROCESS METER SERIES SPECIAL www.fema.es SPECIAL APPLICATIONS Loop YOUR METER  ! 5137r01...
  • Page 2: Table Of Contents

    INDEX The instrument is provided with the following elements: • 1 x instrument LP4 • 1 x plug-in screw terminals 1.  Material included ..... . . 2 •...
  • Page 3: Front And Rear View

    (see section 13.1). The ‘input low’ and the ‘input high’ parameters can still be directly accessed from the ‘tools’ menu (see section 13.5) or from the ‘field correction’ function (see section 13.2). w w w. fema . es...
  • Page 4: Configuration System

    CONFIGURATION SYSTEM HOW TO ENTER THE ‘CONFIGURATION MENU’ The LP4 loop powered process meter is fully configurable from the With the instrument in ‘normal mode’ of operation (see section 10), press instrument front panel, through a configuration system made of three the ‘SQ’...
  • Page 5: How To Operate The 'Fast Access' Menu

    Table 6 Example of ‘Fast access’ menu with all functions set to ‘on’ ‘Memory of max.’ ‘Memory of min.’ Measured value Exit See section 13.4 for a list and a description of available functions. w w w. fema . es...
  • Page 6: Configuration Menu

    ‘Steps’ (StEP) function configures the reading to be done in steps of 1, 2, 5, 10, 20 or 50 counts. • the ‘Left zeros’ (LZEr) parameter activates the reading with active left zeros. FEMA · MANUFACTURING FOR INDUSTRIAL AUTOMATION...
  • Page 7: Key Up (Fast Access)

    ‘0000’. • at the ‘Factory reset’ (FAct) parameter select ‘yes’ to activate the default factory configuration (see section 19 for a list of factory default parameters). w w w. fema . es...
  • Page 8: Technical Specifications

    92 x 44 mm deep 91  mm including terminals Panel TEMPERATURE 44 mm cut-out (1.74 in.) operation from 0 to +50 ºC 92 mm storage from -20 to +70 ºC (3.63 in.) ‘warm-up’ time 15 minutes PACKAGING size 116 x 114 x 50 mm material cardboard weight <150  grams FEMA · MANUFACTURING FOR INDUSTRIAL AUTOMATION...
  • Page 9: Precautions On Installation

    Extended warranty available at (see section 4) According to directive 2012/19/EU, electronic equipment must be recycled in a selective and controlled way at the end of its useful life. w w w. fema . es...
  • Page 10: Application Examples

    PLC. Just cut the loop, and connect O-ring for IP65 front protection the LP4. Place it close to the transmitter to provide instant information to the local operator and maintenance personnel. Table 9 Example of LP4 ‘loop powered meter’...
  • Page 11: Accessories

    ‘mVdc’, ‘mVac’, ‘mAdc’, ‘mAac’, ‘%’, additional mechanical and IP65 ‘ºC’, ‘ºF’, ‘ph’, ‘m’, ‘cm’, ‘mm’, ‘bar’, ‘psi’, front protection. ‘Pa’, N’, ‘Ω’, ‘KΩ’, ‘W’, ‘kW’, ‘MW’, ‘kV’, ‘kA’, ‘m/min’, ‘rpm’, ‘l’ (1 set included with each instrument) w w w. fema . es...