ADF:
Replace the feed belt and reverse roller at 100k originals
Replace the pick-up rollers at 120k originals
Lubricate the feed drive gear (EM-50L grease)
Clean other parts
Scanner:
600k: Clean APS sensors, ADF exposure glass, toner
1200k: Clean white plate, mirrors, main exposure glass,
No alcohol
PCDU:
600k: Drum cleaning unit components
1000k: Charge corona unit components
1200k: Clean Potential sensor, quenching lamp, used toner
1800k: Replace the gears (Drum cleaning unit)
2500k: Drum
Slide 139
No additional notes
PM Intervals - 1
shield glass
guide rails
bottle
139