Ricoh BR-C1a Basic Service Training page 412

Table of Contents

Advertisement

Slide 412
No additional notes
Bottle Full Sensor
 Normally, the used toner bottle
sensor switches on/off
repeatedly during the rotation of
the coils.
 When the used toner bottle
becomes full, the load on the
transport coils means that the
torque limiter on the drive gear
cannot turn.
 So, the sensor stops switching
on/off. If this condition
continues for longer than 3
seconds, the bottle is full.
 The machine stops. If there is
 The capacity of the used toner
bottle is about 1200 K sheets.
412
a job in progress, it will stop
immediately and an alert will
appear on the operation panel.
BR-C1 Training