Invert/Exit (Face-down Delivery) - 1
Slide 470
JG: Junction gate
After the paper passes under
the heat pipe, the exit
junction gate guides the
paper to the invert/exit path.
When the leading edge of the
paper passes the exit
junction gate sensor [F], the
exit junction gate motor [C]
rotates cam [D], which opens
the exit junction gate [E].
This opens the invert path.
When the exit JG sensor [A]
detects the leading edge of
the paper, the invert entrance
motor [B] turns on and feeds
the paper down into the
inverter unit.