5. Function of terminal

5.1 Power input (POWER)
200 W, 400 W, 750 W
Terminal Brock
Terminal
symbol
B1
for external regen-
erative resistor
P
L3
Power input
L2
L1
Recommended pin terminal: TGN TC-1.25-9T (Nichifu Co.,Ltd.)
How to wiring:
Please use a single wire or rod terminal and insert as far into the connection hole.
Recommended rod terminal: TGN TC-1.25-9T(NICHIFU), Applicable wire size: AWG20 to 16.
In case of single wire: Strip length 10 mm (reference), Applicable wire size: AWG20 to 14.
How to remove wiring:
Using a flathead screwdriver with a blade width of 2.6 mm, push the Wire extraction button of
the terminal block vertically and remove the electric wire. Be careful not to apply excessive
force at this time. (Approximately 20 N or less)
* Please check tools etc. necessary for terminal crimp on the home page of terminal
manufacturer or contact terminal manufacturer.
* Since the strip length of the wire depends on the type of wire etc., please decide the optimum
strip length according to the processing condition.
50 W, 100 W
Connector: Molex 5569-10A-1210 or equivalent
Terminal
Pin No.
symbol
3
5
6
8
10
1,2,4,7,
(NC)
9
CAUTION: To prevent unforeseen circumstances due to poor contact etc., install and wire
so that no stress such as pulling is applied to the terminal block through the
cable.
5.2 Grounding terminal ( )
Terminal for grounding the amplifier.(M4×2pieces)
Fasten only one wire to one terminal.
Fasten torque:0.8-1.2 N・m
Terminal name
Connect for external regenerative resister in case.
DV0P2890 for 100 V
DV0PM20068 for 200 V
Connect the terminal to commercial power supply con-
forming to voltage specification. In case of single-phase
connect L1 and L2.
Terminal
name
for external
B
regenerative
P
resistor
L3
Power input
L2
L1
-
Description of function
Description of function
Connect for external regenerative resister in case.
DV0P2890 for 100 V
DV0PM20068 for 200 V
Connect the terminal to commercial power supply con-
forming to voltage specification. In case of single-phase
connect L1 and L2.
Do not connect anything.
№ SX-DCT00221 -5-