5.3 Connector for motor connection (MOTOR)
MOLEX 5569-8A-1210 or equivalent
Terminal number
1
2
3
4
5
6
7
8
■High voltage is applied to motor wire and CS signal line; Use caution for avoiding
electric shock.
■ Use a motor extension cable (option) for extending motor wire.
■ No. 4 to 8 terminals of option cable are shielded. But the shield material is
not grounded.
Please do not ground the shield material in order to avoid malfunctions or
damages.
■ No. 4 to 8 terminals of option cable are not isolated from commercial power
source. Use care to avoid electric shock and grounding fault.
5.4 Connector for communications (SER)
MOLEX 85503-0001 or equivalent
Terminal number
1
2
3
4
5
6
7
8
■The pin numbers are shown in the figure at right.
■The connection cable(DV0P383**) for Digital key pad is needed to connect
with the Digital key pad. (sold separately)
■The connection cable(DV0P383**) for Digital key and PC cable (DV0P4140)
are needed to use RS232C communication control software「PANATERM for BL」.
Terminal name
U
V
W
5VS
5 V (not insulated from power supply)
CS1
CS2
CS3
GNDS
GND (not insulated from power supply)
Terminal name
+5VL
SOT
Digital key pad communication
SIN
RS485+
RS485-
GNDL
Digital key pad communication
SCK
Description of terminal
Motor U phase
Motor V phase
Motor W phase
CS signal
CS signal
CS signal
Description of terminal
Do not connect anything.
power supply 5 V
or PANATERM for BL
Connect RS485+
Connect RS485-
Signal ground
№ SX-DCT00221 -6-