Panasonic MINAS-BL KP Series Reference Specifications page 50

Brushless amplifier
Table of Contents

Advertisement

ENQ: Request for sending
When request for sending is sent to the amplifier, response data changes depending on the status of amplifier.
Response data is returned in the priority order below:
1
When amplifier is powered on
2
When receiving data reading / parameter reading
3
When the status of amplifier changes
4
Other cases than the above
・Initial request response is answered to the initial data request for sending after the amplifier is powered on.
・When the amplifier ID is 80h (128), request for sending to the amplifier is ignored.
1. When the amplifier is powered on
①Host →Amplifier (Request for sending)
SOH
Amplifier ID
②Amplifier →Host (Request of data)
SOH
Host ID
Amplifier ID
③Host →Amplifier (Response of result)
SOH
Amplifier ID
④Amplifier →Host (Communication completion response)
SOH
Host ID
Amplifier ID
・When initial response is confirmed, write parameters as necessary.
2. When receiving data reading / parameter reading
See "$R: Data reading/Parameter reading command" on page before.
3. When the status of amplifier changes
①Host →Amplifier (Request for sending)
SOH
Amplifier ID
②Amplifier →Host (Request of data)
SOH
Host ID
Amplifier ID
③Host →Amplifier (Response of result)
SOH
Amplifier ID
④Amplifier →Host (Communication completion response)
SOH
Host ID
Amplifier ID
・The amplifier saves the status when executing request for sending, and emits the above response when the
status in receiving the next request for sending has changed. Read data is the same as in reading data number 8103h.
・When the amplifier is powered on, in the case where request for sending is sent continuously, data update
request response is answered after initial request response is made.
4. Cases other than the above
①Host →Amplifier (Request for sending)
SOH
Amplifier ID
②Amplifier →Host (Communication completion response)
SOH
Host ID
Amplifier ID
・The amplifier makes communication completion response because data is not requested from the host,
and the status of amplifier has not changed.
ENQ
Host ID
STX
Command
ACK
Host ID
EOT
ENQ
Host ID
STX
Command
ACK
Host ID
EOT
ENQ
Host ID
EOT
Initial request response is answered.
Refer to data reading command processing.
Data update request is answered.
Communication completion response is answered.
Data number
Data number
№ SX-DCT00221 -47-
ETX BCC
Reading data
ETX BCC
Reading data