Safety; Intended Use; System Requirements - Pilz PNOZ ml1p Operating Manual

Configurable safety systems pnozmulti
Hide thumbs Also See for PNOZ ml1p:
Table of Contents

Advertisement

Safety

3
Safety
3.1

Intended use

The expansion module is used for the point-to-point connection of safe virtual inputs and
outputs between two base units.
The expansion module may only be connected to a base unit from the PNOZmulti system
(please refer to the document "PNOZmulti System Expansion" for details of the base units
that can be connected).
The configurable small control systems PNOZmulti are used for the safety-related interrup-
tion of safety circuits and are designed for use in:
E-STOP equipment
}
Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1
}
The coated version of the product PNOZ ml1p is suitable for use where there are increased
environmental requirements (see
The following is deemed improper use in particular:
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see
}
3.2

System requirements

Please refer to the "Product Modifications PNOZmulti" document in the "Version overview"
section for details of which versions of the base unit and PNOZmulti Configurator can be
used for this product.
Operating Manual PNOZ ml1p
21575-EN-06
Technical details [
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
22]).
Technical details [
22]).
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

773540773545

Table of Contents