For information about upgrading your firmware, refer to the Sun SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
Resetting the XSCF Firmware
After updating the XCP firmware, use the rebootxscf(8) command to reset the
XSCF.
Functionality Issues and Limitations
This section describes known issues and limitations at the time of this release.
Limitation for Power Consumption Monitoring
Function
The amount of power consumption may not be indicated correctly in the MIB
information, in the showenvironment power command output, and on the XSCF
Web in the following cases; and you should wait for one minute and check the value
again.
During the server powering on or powering off, or for a while after the power-on
■
or power-off complete
During the active replacement of power supply unit, or for a while after the active
■
replacement complete
General Functionality Issues and Limitations
Note – For power-on after power-off, wait at least 30 seconds before turning the
system power back on, by using the main line switch or the circuit breakers on the
distribution panel.
6
Sun SPARC Enterprise M3000 Server Product Notes for XCP 1090 • August 2009