Starting Problems (continued)
Condition
________________________________________________________________________________________________________________________________________________________
Engine cranks, but does not start.
________________________________________________________________________________________________________________________________________________________
Engine cranks (but should not)
with traction pedal out of neutral.
________________________________________________________________________________________________________________________________________________________
Engine cranks (but should not)
with cutting unit clutch switch ON.
Troubleshooting
(Reelmaster 216)
Possible Cause
Engine wiring connector or wires
loose, corroded or damaged.
Engine, engine ignition, or fuel sys-
tem problem.
Interlock module faulty.
Traction neutral switch out of ad-
justment or faulty.
Cutting unit clutch switch faulty.
Page 6 - 10
Correction
Repair wiring.
See Troubleshooting section of
Kohler Magnum Engine Service
Manual.
Replace interlock module.
Test switch and replace if faulty.
Make sure wires are connected
to "COMMON" and "NORMALLY
OPEN" (N.O.) terminals.
Replace switch.
®
Reelmaster
216/216-D