38
36
7. Place the pump housing (Item 8) with the large cavity
up. Use care not to scratch the port face surface.
8. Using a 3/16 in. diameter drift punch, drive spring pin
(Item 38) ou t o f tr u nnion and control sh afts
(Item 12 & 28). The pump housing is provided with a
cast recess so that the pins can be driven free of
trunnion and control shafts.
9. Drive each trunnion shaft out of swashplate bore
toward outside of housing. Once clear of swashplate
®
Reelmaster
216/216-D
37
6
35
28
9
Figure 38
bore, the shaft can be removed easily. The swashplate
(Item 37) is then removed from the pump housing.
10. Inspect the needle bearings (Item 9). If replacement
is required press out the old bearings.
11. Remove retaining ring (Item 36) from housing, then
press out shaft and bearing assembly (Item 6, 34 & 35).
The bearing (Item 35) can be removed from shaft, if
necessary, after removing retaining ring (Item 34).
Page 5 - 35
34
8
12
Repairs